Residual DNA · Host Cell Protein · Process Residuals · Microbial Safety

As biologics expand across cell and gene therapy, antibody drugs, recombinant proteins, mRNA therapeutics, and vaccines, quality control requirements are becoming increasingly stringent.

Yeasen provides integrated QC solutions covering sample preparation, residual DNA detection, HCP and residual enzyme analysis, process-related impurity testing, and biological safety testing. Built on in-house technologies and an ISO 13485 quality system, our solutions support critical QC checkpoints from upstream processing to final product release.

2. QC Solutions Across Biopharma Applications

Different modalities share many of the same QC targets, while specific testing requirements depend on the host cell, manufacturing process, and product type.

Explore QC solutions across five major biopharma application

2.1 Cell Therapy

From cell expansion and genetic modification to final product release, QC focuses on residual host-cell components, process-related impurities, microbial contamination, and genetic safety. 

Figure 1 — Cell Therapy process flow.
Figure 1 — Cell Therapy process flow.

Flow chart copy:  Stage 1: Plasmid Construction & Production  →  Stage 2: Lentiviral Vector Production  →  Stage 3: T Cell Isolation · Activation · Transduction  →  Stage 4: CAR-T Cell Expansion & Harvest  →  Stage 5: Formulation & Release Testing

Primary QC Solutions

HCD (HEK293 · plasmid · E. coli) · HCP (HEK293) · Biological risk & CGT safety (RCL · RCR · CAR/TCR copy number · mycoplasma · endotoxin)

2.2 Gene Therapy

AAV · Lentivirus · Adenovirus · Oncolytic Virus

Gene therapy manufacturing requires control of host-cell residues, process-related impurities, and replication-competent viral contaminants throughout vector production.

Figure 2 — Gene Therapy process flow. 

Figure 2 — Gene Therapy process flow.

Flow chart copy:  Stage 1: Plasmid Construction & Production  →  Stage 2: Viral Packaging & Production  →  Stage 3: Virus Purification (Lysis · Nuclease · Chromatography)  →  Stage 4: Harvest, Formulation & Release

Primary QC Solutions

HCD (HEK293 · Sf9/baculovirus · E. coli) · Process residuals (nuclease) · Biological risk & CGT safety (rcAAV2 · RCA · RCL · RCR)

2.3 Antibody Drugs & Recombinant Proteins

Mammalian · Yeast · Prokaryotic Expression Systems

QC requirements vary with the expression system and downstream process, with key targets including residual host-cell DNA, HCP, and process-related reagents.

Figure 3 — Antibody Drugs & Recombinant Proteins process flow.

Figure 3 — Antibody Drugs & Recombinant Proteins process flow.

Flow chart copy:  Stage 1: Cell Bank Establishment & Characterisation  →  Stage 2: Cell Culture (Mammalian / Yeast / Prokaryotic Systems)  →  Stage 3: Harvest & Purification  →  Stage 4: Formulation & Release Testing

Primary QC Solutions

HCD (CHO · E. coli · yeast) · HCP (CHO · E. coli · Pichia) · Process residuals (Protein A · BSA · nuclease)

2.4 mRNA Vaccines & Therapeutics

From plasmid template to LNP-encapsulated drug product release. mRNA manufacturing introduces process-specific QC requirements, including residual DNA, process enzymes, and dsRNA generated during RNA synthesis.

Figure 4 — mRNA Vaccines & Therapeutics process flow. 

Figure 4 — mRNA Vaccines & Therapeutics process flow.

Flow chart copy:  Stage 1: Plasmid Template Production  →  Stage 2: In Vitro Transcription (IVT)  →  Stage 3: Capping, Tailing & Purification  →  Stage 4: LNP Encapsulation & Formulation  →  Stage 5: Drug Product Release Testing

Primary QC Solutions

HCD (E. coli · plasmid DNA residue) · Process residuals (T7 RNA polymerase · capping enzyme · RNase inhibitor · dsRNA)

2.5 Vaccines

Vero · MDCK · CHO · Yeast and Other Platforms
Vaccine manufacturing requires control of residual host-cell components, process-related impurities, and biological safety throughout production.

Figure 5 — Vaccines process flow (four stages). Recommended QC products at each stage: see the Stage Product List workbook. 

Figure 5 — Vaccines process flow (four stages). Recommended QC products at each stage: see the Stage Product List workbook.

Flow chart copy:  Stage 1: Cell Substrate Preparation & Characterisation  →  Stage 2: Seed Lot · Culture & Harvest  →  Stage 3: Purification & Nucleic Acid Clearance  →  Stage 4: Formulation & Release Testing

Primary QC Solutions

HCD (Vero · MDCK · CHO · yeast) · HCP (CHO) · Biological risk & CGT safety (mycoplasma · endotoxin · cell species Identification)

3. Product Coverage Across Applications

Yeasen QC portfolio is organized around key testing needs rather than individual modalities, making it easier to select the right solution based on your host cell, process step, and QC target.

Table 1. Product series coverage by application

Product series

Cell Therapy

Gene Therapy

Antibody Drugs & Recombinant Proteins

mRNA Vaccines & Therapeutics

Vaccines

Host cell residual DNA (HCD) detection

●

●

●

○

●

Host cell protein (HCP) & residual enzyme ELISA

○

○

●

○

○

Process-related impurity & residual reagent control

○

●

●

●

●

Biological risk & CGT safety testing

●

●

○

○

●

● Core solution    ○ Applicable / selected products    — Not required

4.  Product Solution — Series Highlights

4.1 Host Cell Residual DNA (HCD) Detection

qPCR-based residual DNA quantification across major expression systems

Yeasen HCD detection solutions quantify residual host-cell DNA from major expression systems, including CHO, HEK293, E. coli, Vero, MDCK, human cells, yeast, and insect cells, with matched magnetic-bead sample preparation and residual DNA size analysis.

Feature

Performance

High Sensitivity

Detection limit down to 0.5 fg/µL

High Precision

Repeatability CV < 10%; intermediate precision < 15%

High Specificity

Host-specific primers show no cross-reactivity between cell lines and no interference from plasmid DNA

Reliable Recovery

Matched magnetic-bead preparation achieves 70–130% host-cell DNA recovery

Fast Time-to-Result

Complete workflow from lysis to qPCR result within 3 hours

Residual DNA Size Analysis

Quantifies both residual DNA amount and fragment-size distribution to support DNA clearance assessment

Series Coverage

10 host cell lines · Plasmid DNA residue · E. coli host cell RNA residue · 4 residual DNA size analysis kits

High Sensitivity

CHO: 0.3 fg/μL

Figure. qPCR detection of CHO DNA at 0.3 fg/μL.


Figure. qPCR detection of CHO DNA at 0.3 fg/μL.

Vero:0.5 fg/μLFigure . qPCR Detection Results of 0.5 fg/μL Vero DNAFigure . qPCR Detection Results of 0.5 fg/μL Vero DNA

HEK293: 10 fg/μL

Figure. qPCR detection of HEK293&nbsp;DNA at 10 fg/μL.Figure. qPCR detection of HEK293 DNA at 10 fg/μL.

E.Coli: 3 fg/μLFigure. qPCR detection of&nbsp;E.Coli&nbsp;DNA at 30 fg/μL.

Figure. qPCR detection of E.Coli DNA at 30 fg/μL.

High Precision

A HEK293 DNA standard sample at 30 pg/μL was tested 10 times. The CV was <15%, meeting the repeatability requirement.

Replicate No.

1

2

3

4

5

6

7

8

9

10

Mean

CV

Measured Value (pg/μL)

29.51

30.02

30.13

30.16

27.99

31.01

31.05

30.95

31.02

29.86

30.17

3.15%


A Vero DNA standard sample at 3 pg/μL was tested 10 times. The CV was <15%, meeting the repeatability requirement.

Replicate No.

1

2

3

4

5

6

7

8

9

10

Mean

CV

Measured Value (pg/μL)

3.10

3.49

3.61

3.55

3.75

3.84

3.54

3.64

3.45

3.48

3.57

5.72%


A
E. coli DNA standard sample at 3 pg/μL was tested 10 times. The CV was <15%, meeting the repeatability requirement.

Replicate #

1

2

3

4

5

6

7

8

9

10

Mean

CV (%)

Measured (pg/μL)

3.16

2.87

2.97

2.86

2.81

2.97

3.14

3.21

3.14

3.10

3.02

4.78

Recovery Ratio (%)

105.33

95.67

99.00

95.33

93.67

99.00

104.67

107.00

104.67

103.33

102.17

—

 

High Specificity

Figure 2. Interference Test Results(E.Coli) 

Figure 2. Interference Test Results(E.Coli)

Interference from genomic DNA commonly used in biopharmaceutical production (HEK293, Vero, CHO) was evaluated. No interference was observed—the amplification curves of interference groups overlapped with those of the control group.

Reliable Recovery

Spiked Recovery in Blank Matrix-E.coli Host Cell DNA Residue Detection Kit

Samples spiked at high (300 pg/μL), medium (3 pg/μL), and low (30 fg/μL) concentrations of E. coli DNA were processed using the magnetic bead-based DNA extraction kit (two independent extractions per sample, each with three technical replicates). Recovery rates for all concentrations fell within 70–130%, with CVs <20%.

Sample Type

Theoretical Concentration

Mean Extraction 1

Mean Extraction 2

Mean Measured Concentration

CV (%)

Recovery (%)

Blank

—

—

—

—

—

—

Recovery Sample 1

300 pg/μL

250.56 pg/μL

262.11 pg/μL

256.33 pg/μL

4.41

85.44

Recovery Sample 2

3 pg/μL

2.29 pg/μL

2.56 pg/μL

2.42 pg/μL

7.09

80.77

Recovery Sample 3

30 fg/μL

33.62 fg/μL

32.61 fg/μL

33.12 fg/μL

14.28

110.39

4.2 Host Cell Protein (HCP) & Residual Enzyme ELISA

Sandwich ELISA for host cell proteins and process-related residual enzymes

Yeasen provides HCP ELISA solutions for CHO, HEK293, E. coli, and Pichia pastoris, together with ELISA kits for residual enzymes used throughout biologics and mRNA manufacturing.

Key Highlights

Feature

Performance

High Sensitivity

LOQ down to the single-digit ng/mL level

High Specificity

Antibodies raised against matched host cell lines

One-Step Option

One-step CHO HCP ELISA format for reduced hands-on time

Regulatory Alignment

Developed and validated in accordance with ChP, USP, EP and ICH Q2(R2) requirements

In-house Development

Capture antibodies, detection antibodies and reference standards developed and manufactured in house

Lot-to-Lot Control

Controlled production processes and traceable quality documentation

Series Coverage: CHO HCP · HEK293 HCP · E. coli HCP · Pichia pastoris HCP

4.3 Process-related Impurity & Residual Reagent Control

Targeted testing for process-specific residuals

Process-related impurities are determined by the manufacturing process and may originate from purification, cleavage, enzymatic modification, or formulation steps.

Yeasen provides ELISA and activity-based assays for a broad range of process residuals.

Feature

Coverage

Broad Process Coverage

Protein A · BSA · Enterokinase · Nuclease · T7 RNA Polymerase · Inorganic Pyrophosphatase · RNase Inhibitor · Vaccinia Capping Enzyme

Nuclease Residual Testing

Assays for UCF.ME™ UltraNuclease and Salt Active UltraNuclease

Enzyme Activity Verification

DNase and RNase activity assays help verify functional clearance

mRNA-specific QC

dsRNA ELISA and residual enzyme testing for key mRNA manufacturing steps

Process-matched Testing

Assays matched to the enzymes used in production for improved process traceability

Series Coverage

Protein A · BSA · Enterokinase · UltraNuclease · Salt Active UltraNuclease · T7 RNA Polymerase · Inorganic Pyrophosphatase · RNase Inhibitor · Vaccinia Capping Enzyme · dsRNA · DNase/RNase Activity · Reverse Transcriptase Activity

4.4 Biological Risk & CGT Safety Testing

Safety testing for microbial contamination and genetic risks

Yeasen provides testing solutions for critical biological risks in cell and gene therapy manufacturing, covering endotoxin, mycoplasma, replication-competent viruses, vector genomes, and cell substrate identity.

Feature

Performance

Endotoxin Detection

Recombinant Factor C kinetic assay as an animal-free alternative to LAL

Rapid Mycoplasma Testing

Real-time qPCR method validated against EP 2.6.7, USP 63 and JP G3

Replication-Competent Virus Testing

RCL · RCR · rcAAV2 · RCA detection

Vector Genome Quantification

CAR/TCR copy number and lentivirus physical titer qPCR

Cell Substrate Identification

Multiplex PCR-based cell species identification

Vector Process Monitoring

HIV-1 p24 ELISA for lentiviral vector production

Series Coverage: Recombinant Factor C Endotoxin · MycAway™ Mycoplasma qPCR · RCL · RCR · rcAAV2 · RCA · SV40 LTA & E1A · CAR/TCR Copy Number · Lentivirus Physical Titer · Cell Species Identification · HIV-1 p24

5. Performance Validation Report Summary

HCD Detection Products

Cat. No.

Product Name

Host / Target

Validation Report

41331ES

HEK293 Host Cell DNA Residue Detection Kit (3G)

HEK293

Validation Report

41316ES

HEK293 Host Cell Residual DNA Size Analysis Kit

HEK293

Validation Report

41308ES

E.coli Host Cell DNA Residue Detection Kit (2G)

E. coli

Validation Report

41337ES

E.coli Host Cell Residual DNA Size Analysis Kit

E. coli

Validation Report

41318ES

E.coli Host Cell RNA Residue Detection Kit

E. coli RNA

Validation Report

41332ES

CHO Host Cell DNA Residue Detection Kit (3G)

CHO

Validation Report

41334ES

CHO Host Cell Residual DNA Size Analysis Kit

CHO

Validation Report

41307ES

Vero Host Cell DNA Residue Detection Kit (2G)

Vero

Validation Report

41314ES

Vero Host Cell Residual DNA Size Analysis Kit

Vero

Validation Report

41319ES

MDCK Host Cell DNA Residue Detection Kit

MDCK

Validation Report

41325ES

Human Host Cell DNA Residue Detection Kit

Human cells

Validation Report

41324ES

S. cerevisiae Host Cell DNA Residue Detection Kit

S. cerevisiae

Validation Report

41328ES

Pichia pastoris Host Cell DNA Residue Detection Kit

Pichia pastoris

Validation Report

41317ES

Hansenula polymorpha Host Cell DNA Residue Detection Kit

Hansenula polymorpha

Validation Report

41330ES

Sf9 and Baculovirus DNA Residue Detection Kit

Sf9 / AcNPV

Validation Report

41323ES

Plasmid DNA Residue Detection Kit

Plasmid DNA

Validation Report

41310ES

SV40LTA&E1A Residue DNA Detection Kit

SV40 LTA / E1A

Validation Report

41321ES

RCA (E1A) Gene Copy Number Detection Kit

RCA (E1A)

Validation Report

41311ES

Replication-competent Lentivirus (RCL) Detection Kit

RCL

Validation Report

41329ES

Replication-competent Retrovirus (RCR) Detection Kit

RCR

Validation Report

41327ES

Replication-competent AAV Serotype 2 (rcAAV2) Detection Kit

rcAAV2

Validation Report

41333ES

Lentivirus Physical Titer qPCR Detection Kit

Lentivirus RNA

Validation Report

41313ES

CAR/TCR Copy Number Detection Kit

CAR / TCR

Validation Report

41341ES

Cell Species Identification Kit (Multiplex PCR Method)

Cell substrate ID

Validation Report

HCP & Process Residual Products

Cat. No.

Product Name

Host / Target

Validation Report

36714ES

CHO HCP ELISA Kit (CHO-K1)

CHO

Validation Report

36730ES

CHO HCP ELISA Kit (One-Step)

CHO-S / CHO-K1

Validation Report

36712ES

E.coli HCP ELISA Kit

E. coli (BL21 / Rosetta)

Validation Report

36721ES

E.coli HCP ELISA Kit (Plasmid)

E. coli plasmid strains

Validation Report

36713ES

HEK293 HCP ELISA Kit

HEK293

Validation Report

36720ES

Pichia pastoris HCP ELISA Kit

Pichia pastoris

Validation Report

36716ES

Protein A ELISA Kit

Protein A leachate

Validation Report

36722ES

BSA ELISA Kit

BSA

Validation Report

20394ES

Enterokinase ELISA Kit

Enterokinase

Validation Report

36701ES

UCF.ME™ UltraNuclease ELISA Kit

UltraNuclease

Validation Report

36703ES

Salt Active UltraNuclease ELISA Kit (High-Salt Tolerant)

High-salt nuclease

Validation Report

36705ES

T7 RNA Polymerase ELISA Kit

T7 RNA polymerase

Validation Report

36706ES

Inorganic Pyrophosphatase ELISA Kit

Inorganic pyrophosphatase

Validation Report

36707ES

Murine RNase Inhibitor ELISA Kit

Murine RNase inhibitor

Validation Report

36709ES

Vaccinia Capping Enzyme ELISA Kit

Vaccinia capping enzyme

Validation Report

36717ES

Double-stranded RNA (dsRNA) ELISA Kit

dsRNA

Validation Report

36723ES

Recombinant Factor C Endotoxin Detection Kit

Bacterial endotoxin

Validation Report

99301ES

HIV-1 p24 ELISA Kit

HIV-1 p24

Validation Report

6.  FAQ

Q1. How do I choose the right QC solution for my product?

Most QC targets are determined by the host cell or manufacturing process rather than the final product type. Select the relevant modality first, then identify the host cell line and process step to determine the appropriate QC series.

Q2. Which regulatory requirements do the kits support?

The kits are developed and validated under an ISO 13485 quality system, with testing aligned with relevant ChP, USP, EP and ICH Q2(R2) requirements. Performance validation reports are available for the listed products.

Q3. How sensitive are the residual DNA detection kits?

Detection limits reach 0.5 fg/µL, with standard curves traceable to national reference standards and CV < 5%.

Q4. How specific are the HCP ELISA kits?

The kits use antibodies raised against matched host cell lines. The LOQ reaches the single-digit ng/mL level.

Q5. Are validation reports and audit documentation available?

Yes. Performance validation reports are available for the listed products. CoA, lot traceability, and method validation documentation are available on request.

Q6. How is residual DNA prepared before qPCR?

Matched Hieff™ magnetic-bead sample preparation kits can be used to prepare qPCR-ready DNA. The workflow from lysis to qPCR-ready DNA can be completed within 3 hours, with 16 / 48 / 96-channel automated extraction options.

Q7. Can these solutions support IND / BLA submissions?

The products have been used in IND filings accepted by the China CDE and U.S. FDA, supporting China–US dual filing strategies.

Q8. How is lot-to-lot consistency controlled?

Key components, including capture antibodies, detection antibodies, reference standards, and selected enzymes, are developed and manufactured in house, with controlled production and lot traceability.