Description
The Pichia pastoris expression system is a highly efficient eukaryotic expression system with post-translational processing modifications, which is commonly used for the stable expression of functional biological products such as recombinant proteins. Products using the Pichia pastoris expression system will inevitably introduce host cell protein (HCP) impurities during the production and purification process, which can reduce the efficacy of the product and lead to adverse toxicity or immune reactions, so it is necessary to ensure that the residual level of HCP in the final product of the biologic product is as low as possible.
ELISA is a simple to use, sensitive and objective test for HCPs. This kit uses the principle of double-antibody sandwich enzyme-linked immunosorbent assay (sandwich ELISA) to detect the residual Pichia pastoris HCP in samples. First, add the Pichia pastoris HCP standard (36720-B) and test sample to the Anti-Pichia pastoris HCP coated microtiter strips (36720-A), then add the diluted biotin labeled Anti-Pichia pastoris HCP antibody (36720-C), and finally add Streptavidin-HRP (36720-D) to form an antibody + antigen + antibody-Biotin + SA-HRP complex. Subsequently, add TMB substrate (36720-H) into the complex to observe color reaction after washing the complex. TMB was converted from colorless to blue and finally to yellow in the presence of termination solution (36720-I) catalyzed by HRPase. Shades of yellow were positively correlated with the amount of Pichia pastoris HCP detected in the sample. This kit can be used for the optimization of the purification process of biologics, the control of impurities in intermediate processes, and the release testing of final products.
The detection range of this kit is 3.125~200 ng/mL; the lower detection limit is 0.5 ng/mL.
Feature
- Highly sensitive: Detecting as little as 0.5 ng/mL of Pichia pastoris HCP residuals in in-process and final biological samples.
- Ensures accuracy: The Pichia pastoris HCP residuals can be accurately detected with a recovery of 75%-125%.
- Specificity: Specific detection of Pichia pastoris HCP without interference from other exogenous proteins.
- Stable: The difference between lot-to-lot is low, the kit property is not impacted under 37℃ for 7 days.
- Easy signal collection: Using Biotin-Streptavidin system, the signal can be stably enlarged.
Application
Residual Pichia pastoris HCP test in biological products
Specification
Sensitivity |
0.5 ng/mL (range 3.125~200 ng/mL) |
Assay Time |
<4 hours |
Assay Principle |
Two-site immunoenzymetric assay |
Signal Amplification |
Biotin-Streptavidin system |
Detection Wavelength |
450nm-630nm |
Product Performance
Product Performance Validation Program |
Reference standards or requirements |
YEASEN |
|
1. Standards for the kit |
Homemade standards are available |
Pichia pastoris HCP Lyophilized powder |
|
2. Linear Range |
Assay Range |
Refer to the actual situation |
3.125~200 ng/mL |
R2 |
≥0.98 |
≥0.99 and above |
|
Detection value CV for each concentration |
CV≤15% |
CV≤5% |
|
3. Accuracy |
Recovery Rate |
50%~150% |
70%~130% and above |
4. Precision |
Repeatability |
CV≤15% |
<10% |
Intermediate precision |
CV≤15% |
<15% |
|
5. Exclusivity |
No interference with Protein products from other sources |
Specific detection of Pichia pastoris HCP without interference from other exogenous proteins |
|
6. Sensitivity |
Limit of quantification |
Reliable quantification of the smallest concentrations of target substances |
1.5 ng/mL |
Limit of detection |
Refer to the actual situation |
0.5 ng/mL |
|
7. Durability |
Reagent Stability |
Evaluating the effect of different storage temperatures on reagent performance |
4°C for 7 days and 37°C for 7 days, with differences from T0 in the range of 80-120% |
Instrument Compatibility |
Kits are used on different devices without affecting the test results |
Compatible with many types of Microplate Reader (eg. Molecular Devices Microplate Readers) |
Components
Components No. |
Name |
36720ES48 |
36720ES96 |
36720-A |
Anti-Pichia pastoris coated microtiter strips |
48 T |
96 T |
36720-B |
Standard: Pichia pastoris HCP (10 μg/mL) |
50 μL |
100 μL |
36720-C |
Detection Antibody: Biotin-conjugated Antibodies (50×) |
150 μL |
300 μL |
36720-D |
Streptavidin-HRP (100×) |
75 μL |
150 μL |
36720-E |
Dilution Buffer 1 |
25 mL |
50 mL |
36720-F |
Wash Buffer Concentrate (20×) |
25 mL |
50 mL |
36720-G |
Dilution Buffer 2 |
15 mL |
30 mL |
36720-H |
TMB Substrate |
6 mL |
12 mL |
36720-I |
Stop Solution |
5 mL |
10 mL |
36720-J |
Plate Sealer |
3 each |
5 each |
Storage
This product should be stored at 2°C ~8°C. Unopened product is valid for one year.
*Upon receipt of the kit, please check whether all components are complete and immediately store them in corresponding condition.
Figures
Precision Display
A) Repeatability
Spiked sample |
Intra-Assay |
||
Duplicates |
Average Conc. (ng/mL) |
CV (%) |
|
S-100 ng/mL |
10 |
103.65 |
7.41% |
S-25 ng/mL |
10 |
23.63 |
1.54% |
S-6.25 ng/mL |
10 |
5.71 |
0.19% |
B) Intermediate precision
Table 1. The precision of Pichia pastoris HCP ELISA was assayed as the above scheme
Spiked sample |
Inter-Assay |
||
Duplicates |
Average Conc. (ng/mL) |
CV (%) |
|
S-100 ng/mL |
30 |
100.35 |
8.32% |
S-25 ng/mL |
30 |
23.27 |
3.87% |
S-6.25 ng/mL |
30 |
5.43 |
7.65% |
10 duplicated were tested at 3 concentrations on the standard curve, and all the CV% were lower than 10% (Table 1A). 3 lot of Pichia pastoris HCP ELISA kits were tested and the CV% were lower than 15% (Table 1B).
Accuracy Validation
A) Dilution linearity
The intermediate purified samples using recombinant proteins expressed by Pichia pastoris (sample protein concentration of 20 mg/mL, HCP concentration of 1024 μg/mL) were subjected to dilution multiplicity mapping to make their HCP residue values within the range of the standard curve. From the following data, it can be concluded that the dilution linearity of the samples determined by this kit was good, and the differences between the measured values of HCP and the theoretical concentration after different multiplicities of dilution were small, the linear recoveries were in the range of 80%~120%, and the detection values of HCP were linearly correlated with the multiplicities of dilution.
Table2 Sample dilution linearity
Sample name |
Dilution factor |
Theoretical value of diluted HCP (ng/mL) |
Actual HCP measurement (ng/mL) |
Recovery ratio (%) |
Recombinant protein intermediate purification samples |
8000 |
128 |
103.239 |
80.66% |
16000 |
64 |
59.414 |
92.83% |
|
32000 |
32 |
32.094 |
100.29% |
|
64000 |
16 |
17.692 |
110.58% |
|
128000 |
8 |
9.491 |
118.64% |
B) Spiking Recovery Rate
After 32,000-fold dilution of the intermediate purified sample using recombinant protein expressed by Pichia pastoris (sample protein concentration 20 mg/mL, HCP concentration 1024 μg/mL), the content of Pichia pastoris HCP in the sample was 12.48 ng/mL.This 32,000-fold diluted sample (referred to as S) was mixed with the standards of each concentration in equal volume, and the results showed that all of the sample spiked recoveries ranged from 80% to 120%. sample spiked recovery experiment, the results showed that the spiked recoveries were all between 80% and 120%.
Spiked recovery % = (measured value of spiked samples - measured value of unspiked samples) / theoretical value (amount of spiked standard) x 100%.
Table3 Sample spiking recovery rate
Sample |
Detection mean (ng/mL) |
Recovery ratio (%) |
S |
12.48 |
/ |
S+200 ng/mL |
94.75 |
82.27% |
S+100 ng/mL |
54.39 |
83.81% |
S+50 ng/mL |
33.43 |
83.82% |
S+25 ng/mL |
23.15 |
85.39% |
S+12.5 ng/mL |
17.98 |
88.04% |
S+6.25 ng/mL |
15.34 |
91.53% |
S+3.125 ng/mL |
14.02 |
98.83% |
Documents:
Safety Data Sheet
Manuals
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Inquiry
You may also like
FAQ
The product is for research purposes only and is not intended for therapeutic or diagnostic use in humans or animals. Products and content are protected by patents, trademarks, and copyrights owned by Yeasen Biotechnology. Trademark symbols indicate the country of origin, not necessarily registration in all regions.
Certain applications may require additional third-party intellectual property rights.
Yeasen is dedicated to ethical science, believing our research should address critical questions while ensuring safety and ethical standards.