RCA (E1A) Copynumber Detection Kit _ 41321ES

YeasenSKU: 41321ES50

Size: 50 T
Harga:
Harga penjualan$1,485.00

Pengiriman dihitung saat pembayaran

Saham:
Dalam stok

Keterangan

The RCA (E1A) Copynumber Detection Kit can be used to quantitatively analyze and detect the potential risk of Replication-competent Adenoviruses (RCA) that may occur in a variety of cellular therapeutic products and gene therapy products associated with the use of adenoviral vectors; and can also be used to quantitatively analyze and detect the presence of residual DNA of the risk gene E1A in biologics from host cells, such as HEK293 and HEK293T cell-derived risk gene E1A residual DNA.

This kit designs specific primers for the E1A gene sequence on adenovirus, and adopts the principle of fluorescence quantitative PCR by probe method to rapidly and specifically detect the risk of replicative adenovirus RCA and the residual DNA of E1A from the host cell, and the limit of quantification can be as low as 4.1 copies/μL, and it contains the RCA (E1A) DNA Control (DNA quantitative reference product). The kit needs to be used together with the the Residual DNA Sample Preparation Kit (Cat# 18461ES).

Feature

  • Compliance with regulations: the products are fully validated according to the requirements of Chp, USP, ICH, etc., and their performance is in line with Chinese and foreign regulations and standards;
  • Guarantee of quality: the raw materials of the kits are all self-developed, and the qPCR Mix and other enzyme products are produced in an ultra-clean enzyme factory;
  • High sensitivity: the lower limit of quantification (LLOQ) was 4.1 copies/uL;
  • High precision: high intra-batch reproducibility CV <10%, small inter-batch variation i.e. intermediate precision CV <15%;
  • Strong specificity: specific detection of RCA (E1A) residual DNA without interference from other exogenous genomic DNA;
  • Strong anti-interference: the introduction of internal quality control (IC) can exclude sample interference, abnormal reaction preparation and other factors, effectively avoiding false negatives.

Application

  • Residual RCA (E1A) DNA test in biological products.

Specifications

Sensitivity

4.1 copies/uL (range 1.64×1011.64×105copies/μL)

Assay Time

~1.5 hours

Assay Principle

Fluorescent probe qPCR method

Required Instruments

Real-time fluorescence quantitative PCR system

Product Performance

Product Performance Validation Program

Reference standards or requirements

YEASEN

1. Standards for the kit

Homemade standards are available

Plasmid DNA containing Adenovirus E1A gene

2. Linear Range

Assay Range

Refer to the actual situation

1.64x101~1.64x105 copies/μL

R2

≥0.98

≥0.99 and above

Slope

-3.1~-3.8

-3.1~-3.6

Amplification Efficiency

84%~109%

90%~109%

3. Accuracy

Recovery Rate

50%~150%

70%~130% and above

4. Precision

Repeatability

CV≤15%

10%

Intermediate precision

CV≤15%

15%

5. Exclusivity

No interference with DNA from other sources

Specific detection of RCA DNA without interference from other exogenous DNA

6. Sensitivity

Limit of quantification

Reliable quantification of the smallest concentrations of target substances

4.1 copies/μL

7. Durability

Reagent Stability

Evaluating the effect of different storage temperatures on reagent performance

4°C for 14 days and 37°C for 14 days, and repeated freeze-thaw 10 times, the kit amplification efficiency is in the range of 90%~109%, R2≥0.99 and above

Instrument Compatibility

Kits are used on different devices without affecting the test results

Compatible with many types of qPCR Instruments (eg. Bio-Rad CFX96 Optic Module, Thermo Scientific ABI 7500, ABI Quant Studio 5)

Components

Components No.

Name

41321ES50

41321ES60

41321-A

RCA (E1A) qPCR Mix

0.75 mL

1.5 mL

41321-B

RCA (E1A) Primer&Probe Mix

200 μL

400 μL

41321-C

DNA Dilution Buffer

1.8 mL×2

1.8 mL×4

41321-D

RCA (E1A) DNA Control (1.64×107copies/μL)

25 μL

50 μL

41321-E

IC*

50 μL

100 μL

*ICInternal control.

Storage

This product should be stored at -25~-15℃ for 2 years.

Both 41321-A and 41321-B should be stored protected from light.

Figures

  • Limit of quantification

RCA DNA at concentrations of 1.64×101copies/uL, 8.2copies/uL, 4.1copies/μL, 2.05copies/μL and 1.64copies/uL were detected, with 10 replicates for each concentration, respectively. The results showed that the CV of RCA DNA was <20% at concentrations of 4.1copies/μL and above. Therefore, the limit of quantification in the RCA DNA residue detection kits was 4.1copies/μL for RCA.

Table 1. Limit of quantification (LOQ) assay results for RCA DNA

 

 

Repetition number

 

Test item

RCA (copies/μL)

Quantity

Return ratio

1

3.77

91.95%

2

4.44

108.29%

3

3.75

91.46%

4

4.31

105.12%

5

4.00

97.56%

6

4.50

109.76%

7

3.56

86.83%

8

3.55

86.59%

9

3.59

87.56%

10

3.66

89.27%

Average value

3.91

\

CV

9.57%

\

Figure 1. 4.1copies/μL RCA (E1A) DNA qPCR assay results

Figure 1. 4.1copies/μL RCA (E1A) DNA qPCR assay results

Documents:

Safety Data Sheet

41321_MSDS_HB250310.pdf

Manuals

41321_Manual_Ver.EN20250310.pdf

Pembayaran & Keamanan

American Express Apple Pay Diners Club Discover Google Pay Mastercard Visa

Informasi pembayaran Anda diproses dengan aman. Kami tidak menyimpan detail kartu kredit atau memiliki akses ke informasi kartu kredit Anda.

Pertanyaan

Anda mungkin juga menyukai

FAQ

Produk ini hanya untuk keperluan penelitian dan tidak ditujukan untuk penggunaan terapeutik atau diagnostik pada manusia atau hewan. Produk dan konten dilindungi oleh paten, merek dagang, dan hak cipta milik Yeasen Bioteknologi. Simbol merek dagang menunjukkan negara asal, belum tentu pendaftaran di semua wilayah.

Aplikasi tertentu mungkin memerlukan hak kekayaan intelektual pihak ketiga tambahan.

Yeasen didedikasikan untuk ilmu etika, meyakini penelitian kami harus menjawab pertanyaan kritis sambil memastikan standar keselamatan dan etika.