SV40LTA&E1A Residue DNA Detection Kit _ 41310ES

YeasenSKU: 41310ES50

Size: 50 T
Harga:
Harga penjualan$955.00

Pengiriman dihitung saat pembayaran

Saham:
Dalam stok

Keterangan

This kit is designed for the quantitative detection of residual host cell DNA—specifically SV40 Large T Antigen (LTA) and Adenovirus E1A sequences—in biopharmaceutical products derived from host cells such as HEK293T.

Utilizing probe-based real-time PCR (qPCR), the assay enables highly specific and rapid quantification of SV40 LTA and E1A residual DNA, with a limit of detection as low as 10¹ copies/μL.

The kit is fully compatible with Yeasen’s Magnetic Bead–Based Residual DNA Sample Preparation Kits (Cat# 18461ES) for streamlined sample processing.

Features

  • Complies with regulations – Fully validated; validation reports available.
  • High-quality reagents – All components in-house developed; enzymes made in ultra-clean facility.
  • Highly sensitive – Detection down to 10¹ copies/μL.
  • Highly reproducible – Low within-run and between-run variability.
  • Highly specific – Detects only SV40 LTA and E1A DNA—no cross-reactivity.
  • Built-in control – Internal Control (IC) flags sample or reaction issues.

Components

Components No.

Name

41310ES50(50 T)
41310ES60(100 T)

41310-A

SV40LTA&E1A qPCR Mix

0.75 mL

1.5 mL

41310-B

SV40LTA&E1A Primer&Probe Mix

200 μL

400 μL

41310-C

DNA Dilution Buffer

2 × 1.8 mL

4 × 1.8 mL

41310-D

SV40LTA&E1A DNA Control (nonliner)

25 μL

50 μL

41310-E

SV40LTA&E1A DNA Control (linear)

25 μL

50 μL

41310-F

IC

50 μL

100 μL

*IC: Internal control.

Storage

This product should be stored at -25~-15for 2 years. Both 41310-A and 41310-B should be stored protected from light.

Applicable Instrument Models

Include but not limited to:

Bio-Rad: CFX96 Optic Module.

Thermo Scientific: ABI 7500; ABI Quant Studio 5.

Figures

1. Detection Range

SV40LTA: Linear range = 1.8 × 10¹ ~ 1.8 × 10⁵ copies/μL, R² = 1.000, amplification efficiency = 100.25%, CV < 15% across all concentrations.

E1A: Linear range = 1.8 × 10¹ ~ 1.8 × 10⁵ copies/μL, R² = 1.000, amplification efficiency = 100.25%, CV < 15% across all concentrations.

Figure 1. SV40LTA standard curve (left) and amplification plot (right)https://www.yeasenbio.com/products/80510

 Figure 1. SV40LTA standard curve (left) and amplification plot (right)

&nbsp;Figure 2. E1A standard curve (left) and amplification plot (right)

 Figure 2. E1A standard curve (left) and amplification plot (right)

2. Limit of Quantitation (LOQ)

SV40LTA & E1A DNA at concentrations of 18, 9, 4.5, 2.25, and 1.8 copies/μL were tested in 10 replicates each. At ≥4.5 copies/μL, CVs were <20%, establishing the LOQ as 4.5 copies/μL.

Figure 3. qPCR detection of SV40LTA(lift) and E1A(right) at 4.5 copies/μL

 

Replicate

Analyte

SV40LTA (copies/μL)

E1A (copies/μL)

Quantity

Recovery

Quantity

Recovery

1

4.66

103.61%

4.87

108.21%

2

4.33

96.29%

4.15

92.26%

3

4.49

99.72%

4.63

102.88%

4

5.08

112.97%

4.86

107.99%

5

6.26

139.11%

5.67

125.93%

6

5.46

121.26%

4.97

110.42%

7

4.79

106.34%

5.50

122.22%

8

5.57

123.83%

5.00

111.20%

9

5.09

113.18%

5.55

123.28%

10

4.62

102.62%

4.97

110.43%

Mean

5.04

\

5.02

\

CV%

11.73%

\

9.13%

\

 Documents:

Safety Data Sheet

40310_MSDS_HB260203

Manuals

40310_Manual_Ver.EN20260203

Pembayaran & Keamanan

American Express Apple Pay Diners Club Discover Google Pay Mastercard Visa

Informasi pembayaran Anda diproses dengan aman. Kami tidak menyimpan detail kartu kredit atau memiliki akses ke informasi kartu kredit Anda.

Anda mungkin juga menyukai

Pertanyaan

FAQ

Produk ini hanya untuk keperluan penelitian dan tidak ditujukan untuk penggunaan terapeutik atau diagnostik pada manusia atau hewan. Produk dan konten dilindungi oleh paten, merek dagang, dan hak cipta milik Yeasen Bioteknologi. Simbol merek dagang menunjukkan negara asal, belum tentu pendaftaran di semua wilayah.

Aplikasi tertentu mungkin memerlukan hak kekayaan intelektual pihak ketiga tambahan.

Yeasen didedikasikan untuk ilmu etika, meyakini penelitian kami harus menjawab pertanyaan kritis sambil memastikan standar keselamatan dan etika.