Hieff NGS™ MaxUp Human/Mouse/Rat rRNA Depletion Kit(rRNA ITS/ETS) 2.0 _ 12726ES

YeasenSKU: 12726ES12

Size: 12 T
Harga:
Harga penjualan$455.00

Pengiriman dihitung saat pembayaran

Saham:
Dalam stok

Keterangan

Hieff NGS™ MaxUp Human/Mouse/Rat rRNA Depletion Kit (rRNA & ITS/ETS) 2.0 utilizes an RNase H digestion method to remove ribosomal RNA (rRNA) and the 45S & ITS/ETS regions from total RNA isolated from human, mouse, and rat samples, thereby enriching messenger RNA (mRNA) and other non-coding RNAs. This kit effectively removes rRNA from both intact and partially degraded total RNA (such as FFPE-derived RNA). Since degraded FFPE samples typically contain a higher proportion of ITS/ETS fragments compared to fresh tissue samples, the inclusion of specific probes targeting the human, mouse, and rat 45S & ITS/ETS regions in this kit significantly increases the proportion of usable sequencing data after depletion.

Features

  • Strong Specificity: Efficiently removes rRNA as well as ITS/ETS regions from human samples, with excellent performance on challenging FFPE samples.
  • Broad Input Compatibility: Suitable for a wide range of input amounts (100 ng to 1 μg).
  • High Removal Efficiency: Achieves >95% removal of rRNA, ITS, and ETS from human, mouse, and rat samples.
  • Consistent Quality: Strict batch-to-batch performance and stability controls ensure reliable results.

Components

Components No.

Name

12726ES12

12726ES24

12726ES96

12726-A

Hybridization Buffer

36 μL

72 μL

288 μL

12726-B

Human Probe Mix (rRNA & ITS/ETS)

24 μL

48 μL

192 μL

12726-C

RNase H Buffer

36 μL

72 μL

288 μL

12726-D

Thermostable RNase H

4 μL

48 μL

192 μL

2726-E

DNase I Buffer

330 μL

660 μL

2x1320 μL

12726-F

DNase l

30 μL

60 μL

240 μL

Applications

  • Gene Expression Research
  • Alternative splicing analysis
  • Detection and discovery of LncRNA(Non coding RNA)
  • dentification of selective polyadenylation sites
  • Fusion gene detection

Storage

This product should be stored at -25~-15℃ for 12 months.

Figures

1. Broad Compatibility Across Input Amounts and Sample Types

Figure 1. Superior rRNA Removal Efficiency Across a Broad Input Range

Figure 1. Superior rRNA Removal Efficiency Across a Broad Input Range

Library preparation was performed using the MaxUp™ rRNA Depletion Kit and a strand-specific RNA Library Preparation Kit on human, mouse, and rat total RNA samples. Unlike traditional kits limited to 1 µg input, MaxUp™ demonstrates consistent and efficient rRNA removal across a wide range of input amounts (100 ng to 1 µg), achieving <1% rRNA residual. 

2. Effective rRNA Removal

&nbsp;Figure 2. Comparison of rRNA Removal Efficiency: Depletion vs. Enrichment

 Figure 2. Comparison of rRNA Removal Efficiency: Depletion vs. Enrichment

Using 1 μg of 293T total RNA, samples were processed using either oligo-dT enrichment or rRNA depletion methods. Sequencing analysis revealed that both methods achieved comparable levels of rRNA removal efficiency.

3. Optimized for FFPOptimized for FFPE & Degraded Samples  

Figure 3. Robust rRNA Depletion Performance in FFPE Samples Across a Wide DV200 Range

Figure 3. Robust rRNA Depletion Performance in FFPE Samples Across a Wide DV200 Range

MaxUp™ is optimized for challenging FFPE RNA, maintaining strong performance even with degraded transcripts. The kit demonstrates consistent and efficient rRNA removal across a broad DV200 range (20%–70%), achieving >98% depletion efficiency with a 100 ng input. This ensures high-quality, low-background library construction, making it highly compatible with low-quality samples (DV200 < 50%) for clinical and archival tissue research.

4. Automation-Ready Stability  

Figure 4. Enhanced Stability and Automation Compatibility&nbsp;

Figure 4. Enhanced Stability and Automation Compatibility 

MaxUp™ features a stabilized RNase H system that eliminates the need for fresh enzyme preparation, making it ideal for automated, high-throughput workflows. The kit maintains superior depletion efficiency (>95%) under various storage conditions, including extended periods at 37°C, RT, and 4°C.

Documents:

Safety Data Sheet

12726_MSDS_HB250805_EN.PDF

Manuals

12726_Manual_HB20260401.pdf

Related Blogs:

rRNA Depletion Kit – Efficient rRNA Removal Across All Sample Types

Pembayaran & Keamanan

American Express Apple Pay Diners Club Discover Google Pay Mastercard Visa

Informasi pembayaran Anda diproses dengan aman. Kami tidak menyimpan detail kartu kredit atau memiliki akses ke informasi kartu kredit Anda.

Anda mungkin juga menyukai

Pertanyaan

FAQ

Produk ini hanya untuk keperluan penelitian dan tidak ditujukan untuk penggunaan terapeutik atau diagnostik pada manusia atau hewan. Produk dan konten dilindungi oleh paten, merek dagang, dan hak cipta milik Yeasen Bioteknologi. Simbol merek dagang menunjukkan negara asal, belum tentu pendaftaran di semua wilayah.

Aplikasi tertentu mungkin memerlukan hak kekayaan intelektual pihak ketiga tambahan.

Yeasen didedikasikan untuk ilmu etika, meyakini penelitian kami harus menjawab pertanyaan kritis sambil memastikan standar keselamatan dan etika.