Keterangan
Hieff NGS™ Full UDI Adapter Kit for Illumina is an adapter kit specifically designed for library preparation on Illumina high-throughput sequencing platforms. The kit contains UDI adapters used for next-generation sequencing (NGS) library preparation. Cat#12333–12336 are provided in plate format (Set1/Set2/Set3/Set4). Each set contains 96 adapters, enabling the construction of up to 384 uniquely dual-indexed libraries.
All reagents included in the kit have undergone strict quality control and functional validation to ensure the stability and reproducibility of library preparation to the greatest extent.
Specifications
|
Cat.No. |
12333ES01 / 12333ES02 |
|
Size |
96×1 T / 96×2 T |
Components
|
Components No. |
Name |
12333ES01 (96×1 T) |
12333ES02 (96×2 T) |
|
12333 |
UDI Adapter 001-096 |
5 μL each |
10 μL each |
Storage
This product should be stored at -25~-15℃ for 2 years.
Notes
1. The concentration of the UDI adapters in this kit is 10 μM. The amount of adapter used for each library preparation should be adjusted according to the requirements of the library preparation kit being used.
2. Do not heat the adapters. Allow them to dissolve slowly at room temperature. The laboratory temperature is recommended to be maintained at 20–25°C. Avoid repeated freeze–thaw cycles. It is recommended to aliquot the adapters for storage, and they may be stored at 4°C for short-term use.
3. The structure of the DNA library constructed using the Hieff NGS™ Full UDI Adapter Kit for Illumina is shown below.

4. For your safety and health, please wear a lab coat and disposable gloves when performing the experiment.
5. This product is for research use only.
Sequence Information
UDI Adapter for Illumina:
i5 Index for Illumina:
5´-AATGATACGGCGACCACCGAGATCTACAC[i5 Index]ACACTCTTTCCCTACACGACGCTCTTCCGATC*T-3´
i7 Index for Illumina:
5´-/5Phos/GATCGGAAGAGCACACGTCTGAACTCCAGTCAC[i7 Index]ATCTCGTATGCCGTCTTCTGCTT*G-3´
The notation [i5 Index] denotes an 8-bp i5 index sequence, and [i7 Index] denotes an 8-bp i7 index sequence.
The corresponding positions of each adapter in the 96-well plate are shown in the figure below.

Documents
Safety Data Sheet
Manuals
Pembayaran & Keamanan
Informasi pembayaran Anda diproses dengan aman. Kami tidak menyimpan detail kartu kredit atau memiliki akses ke informasi kartu kredit Anda.
Anda mungkin juga menyukai
Pertanyaan
FAQ
Produk ini hanya untuk keperluan penelitian dan tidak ditujukan untuk penggunaan terapeutik atau diagnostik pada manusia atau hewan. Produk dan konten dilindungi oleh paten, merek dagang, dan hak cipta milik
Aplikasi tertentu mungkin memerlukan hak kekayaan intelektual pihak ketiga tambahan.

