Hieff NGS™ Hyb & Wash Kit with Universal Blocking Oligo for Illumina _ 12245ES

YeasenSKU: 12245ES04

Size: 4 T
Prix:
Prix ​​de vente$140.00
Action:
En stock

The Hieff NGS™ Hyb & Wash Kit with Universal Blocking Oligo for Illumina is a capture hybridization and wash reagent specifically developed for YEASEN targeted capture product lines. It utilizes novel double-stranded DNA probes (100-mer) to capture and enrich target DNA for high-throughput sequencing. The carefully optimized single-tube hybridization buffer system delivers more stable and superior capture performance. With outstanding product performance, enhanced sensitivity, and specificity, the NGS targeted capture kit is widely applied in research areas such as novel molecular diagnostics and detection. All reagents provided in the kit have undergone rigorous quality control and functional validation, ensuring maximum experimental stability and reproducibility.

Specifications

Cat.No.

12245ES04 / 12245ES24 / 12245ES96

Size

4 T / 24 T / 96 T

Components

Components No.

Name

12245ES04

12245ES24

12245ES96

BOX-I

12245-A

Hyb Human Block

20 μL

120 μL

540 μL

12245-B

RNase Block

20 μL

120 μL

540 μL

12245-C

Hyb Buffer v2

80 μL

480 μL

2*1080 μL

BOX-II

12245-D

Binding Buffer

3.5 mL

21 mL

84 mL

12245-E

Wash Buffer 2 v2

4 mL

24 mL

108 mL

12245-F

Wash Buffer 1

880 μL

5.3 mL

24 mL

BOX-III

12245-G

Post PCR Master Mix

110 μL

660 μL

2*1350 μL

12245-H

Post PCR Primer for Illumina (25 μM)

8 μL

48 μL

192μL

12245-I

Universal Blocking Oligo for Illumina

8 μL

48 μL

200 μL

Note: RNase Block* prevents RNA degradation and is used for RNA probe capture panels. If using 12244ES (DNA probes), this component is not required.

Feature

Excellent Compatibility: Compatible with both DNA capture probes and RNA capture probes.

Broad Applicability: Suitable for multiple application areas including tumor companion diagnostics, drug efficacy assessment, genetic screening, and molecular breeding.

Easy Operation: Single-tube workflow with simple steps and good compatibility.

Low Equipment Dependence: Magnetic bead concentration can replace vacuum centrifugation.

Application Case

I. The Hieff NGS™ Hyb & Wash Kit is compatible with probes from other manufacturers, delivering more uniform data.

Uniformity performance of the Hieff NGS™ Hyb & Wash Kit hybridization and wash systemcombined with a competitor’s 3 Tumor Panel. Following the manufacturer’s operating instructions, sequencing was performed on the NovaSeq 6000 platform with PE150. The bar chart represents the size of regions with different GC content in the target area, and the curve represents the coverage depth of regions with different GC content.

Storage

BOX-I: Store at -25~-15°C. Valid for 1 year.

BOX-II: Store at room temperature. Valid for 1 year.

BOX-III: Store at -25~-15°C. Valid for 1 year.

Documents:

Safety Data Sheet

Storage

BOX-I: Store at -25~-15°C. Valid for 1 year. BOX-II: Store at room temperature. Valid for 1 year. BOX-III: Store at -25~-15°C. Valid for 1 year.

FAQ

Citations

Documents

Applications

Vous pouvez aussi aimer

Enquête

FAQ

Le produit est destiné à des fins de recherche uniquement et n'est pas destiné à un usage thérapeutique ou diagnostique chez l'homme ou l'animal. Les produits et le contenu sont protégés par des brevets, des marques déposées et des droits d'auteur appartenant à Yeasen Biotechnology. Les symboles de marque indiquent le pays d'origine, pas nécessairement l'enregistrement dans toutes les régions.

Certaines applications peuvent nécessiter des droits de propriété intellectuelle tiers supplémentaires.

Yeasen se consacre à la science éthique, estimant que nos recherches doivent répondre à des questions cruciales tout en garantissant la sécurité et les normes éthiques.