Description
The Hieff™ Fast Cell Direct Probe RT-qPCR Kit is designed for quantitative gene expression analysis of various animal cells, including adherent and suspension cell lines, primary cultured cells, various stem cells, and iPS cells.
Eliminating the need for RNA extraction, this kit allows for direct qPCR analysis. It features a simple, low-error workflow that efficiently completes all steps—from template preparation and reverse transcription to gene expression analysis—in as little as 1.5 hours. The kit includes both reverse transcription and quantitative detection reagents, facilitating easy and rapid gene expression analysis.
Features
Complete Workflow Solution: Includes cell lysis reagent, wash buffer, gDNA removal reagent, reverse transcription mix, and probe-based qPCR master mix
Fast & Convenient: Complete RNA extraction, reverse transcription, and qPCR workflow in as little as 1.5 hours
High Sensitivity & Reproducibility: Improved amplification performance across genes with varying GC content and excellent repeatability
Excellent Inhibitor Tolerance: Compatible with up to 55% cell lysate input
Outstanding Stability: Stable for 7 days at 4°C; fully premixed qPCR system remains stable for 48 hours
Components
|
Components No. |
Name |
11173ES40 |
11173ES60 |
|
11173-A |
FCD Lysis Buffer* |
2 mL |
5 mL |
|
11173-B |
FCD Washing Buffer* |
8 mL |
20 mL |
|
11173-C |
FCD Stop Solution* |
100 μL |
250 μL |
|
11173-D |
DNase I* |
80 μL |
200 μL |
|
11173-E |
4× Hifair™ FCD RT Mix* |
200 μL |
500 μL |
|
11173-F |
2× Hifair™ FCD Probe qPCR Mix* |
2 mL |
5 mL |
|
11173-G |
RNase Free H2O |
2 mL |
5 mL |
[Note]: *If the supplied amount is insufficient, the Lysis set (Cat#16814ES), RT set (Cat#16815ES), and qPCR set (Cat#16816ES) are available for separate purchase.
Storage
Store unopened kits (11173-A and 11173-B) at -25 ~ -15°C. Once thawed, store at 4°C and take precautions to prevent contamination. For long-term storage, keep all other components at -25 ~ -15°C. Valid for 1 year.
Figures
1. High Sensitivity

Figure 1. Comparison of gene expression analysis:
Gene expression analysis using 293 cells in different states as templates. Samples containing 10³, 10⁴, 10⁵, and 10⁶ cells were detected using Yeasen 11173ES and supplier T* respectively. The results demonstrate that Yeasen 11173ES consistently yields lower Ct values than supplier T* across all cell input amounts, indicating superior sensitivity and better reproducibility.
2. High Detection Efficiency

Figure 2. Performance evaluation: Direct Amplification vs. Traditional RNA Extraction.
Using 293 cells as the template, gene expression levels were detected by both direct lysis and conventional RNA extraction workflows with the reverse transcription and qPCR components included in the kit. The results demonstrated that the direct amplification workflow of 11173ES delivers performance comparable to traditional time-consuming RNA extraction methods, while offering a faster and more efficient solution.
3. Excellent Inhibitor Tolerance

Figure 3. Inhibition Resistance Test
(a) Reverse Transcription (RT) System: The 11173ES RT system tolerated up to 55% cell lysis product, demonstrating robust resistance to inhibition.
(b) qPCR System: The 11173ES qPCR system tolerated up to 46% cDNA input, maintaining efficient amplification even in the presence of high concentrations of lysis-derived cDNA.
4. Excellent Stability

Figure 4. Evaluation of pre-mixed qPCR system stability.
Stability was assessed by incubating the fully pre-mixed qPCR system (containing cDNA, primers, probes, and H2O) at various temperatures for up to 48 hours. The consistent Ct values indicate that the 11173ES qPCR system is highly stable, offering a robust solution that accommodates flexible experimental schedules and operational needs.
Documents:
Safety Data Sheet
11173_MSDS_HB260511_EN.PDF
Manuals
Paiement et sécurité
Vos informations de paiement sont traitées en toute sécurité. Nous ne stockons pas les détails de la carte de crédit ni accès aux informations de votre carte de crédit.
Vous pouvez aussi aimer
Enquête
FAQ
Le produit est destiné à des fins de recherche uniquement et n'est pas destiné à un usage thérapeutique ou diagnostique chez l'homme ou l'animal. Les produits et le contenu sont protégés par des brevets, des marques déposées et des droits d'auteur appartenant à Yeasen Biotechnology. Les symboles de marque indiquent le pays d'origine, pas nécessairement l'enregistrement dans toutes les régions.
Certaines applications peuvent nécessiter des droits de propriété intellectuelle tiers supplémentaires.
Yeasen se consacre à la science éthique, estimant que nos recherches doivent répondre à des questions cruciales tout en garantissant la sécurité et les normes éthiques.

