Hieff NGS ™ RNA Cleaner -12602es

YeasenSKU: 12602ES03

Størrelse: 1 ml
Pris:
Salgspris$85.00
Lager:
På lager

Hieff NGS™ RNA Cleaner kombinerer effektive magnetiske perler og et unikt buffersystem, som specifikt kan binde RNA og effektivt fjerne proteiner, saltioner og andre urenheder. Det bruges ofte til at oprense totale RNA-prøver efter rRNA-fjernelse, in vitro-transskriberede RNA-produkter, RNA-mærkede produkter og syntetiske RNA'er. Og det oprensede RNA er velegnet til RNA-bibliotekskonstruktion, RT-PCR, qRT-PCR, chipanalyse, Northern Blot og RNAi-eksperimenter.

Specifikationer

Produkt Linje RNA ren
Starter Materiale RNA
Kompatibilitet RNA
Isolation Teknologi Magnetisk perle
Finale Produkt Type RNA
For Bruge Med (Anvendelse) RNA oprydning

Komponenter

Ingen. Navn 12602ES03 12602ES08 12602ES56
12602 Hieff NGS™ RNA renser 1 ml 5 ml 60 ml

Opbevaring

2℃ ~ 8℃ opbevaring, gyldig i et år. Undgå at fryse!

Figurer

Figur 1. Effekt af RNA-oprensning på genekspression.

qRT-PCR Ct-værdier af RNA-prøver før og efter brug af det totale RNA-oprensningskit.

Storage

This product should be stored at 2~ 8℃ for 12 months.

FAQ

There is no specific reference. You can first refer to the system in the user manual. For a single reaction with a 50 μl volume of sample, using 1.8 to 2 times the magnetic beads (100 μl magnetic beads) can purify 0.5 - 5 μg RNA.
Yes, small RNA can be recovered. The recovery rate has not been specifically tested. We usually use it for the purification of Total RNA.
For normal magnetic beads, when they stand still, the microbeads separate from the buffer and gather at the bottom of the bottle. Before using them, shake to mix evenly, and the microbeads are evenly distributed in the buffer. For abnormal magnetic beads, due to factors such as β-mercaptoethanol, DTT, and large pH differences, it affects the uniformity of the magnetic beads, causing the beads to become thick, aggregate into blocks, or have the phenomenon of sticking to the wall.
Storing at room temperature will have some impact on the recovery performance of the magnetic beads. It is not recommended to leave them at room temperature for too long. After use, it is recommended to store them at 4℃. The separation effect of PEG is easily affected by pH, temperature, etc.
12602: RNA purification magnetic beads; 12603: Complete mRNA capture magnetic beads for eukaryotes
1) Sample: The sample contains high levels of sugar or protein; the sample buffer and the magnetic bead buffer are incompatible;
2) Magnetic beads: The magnetic bead buffer has been contaminated.
3) Operation: The drying time should not be too long (generally, it should not exceed 5 minutes)
The product cannot be reused. The ethanol elution step will affect the performance of the surface-active groups on the magnetic beads.
It is not recommended. DNA magnetic beads for purifying RNA may cause RNA degradation. The system in RNA magnetic beads is more conducive to maintaining the stability of RNA structure and preventing its degradation.

Citations

Applications

Du kan også lide

Forespørgsel

FAQ

Produktet er kun til forskningsformål og er ikke beregnet til terapeutisk eller diagnostisk brug hos mennesker eller dyr. Produkter og indhold er beskyttet af patenter, varemærker og ophavsrettigheder ejet af Yeasen Biotechnology. Varemærkesymboler angiver oprindelseslandet, ikke nødvendigvis registrering i alle regioner.

Visse applikationer kan kræve yderligere tredjeparts intellektuelle ejendomsrettigheder.

Yeasen er dedikeret til etisk videnskab og mener, at vores forskning bør adressere kritiske spørgsmål og samtidig sikre sikkerhed og etiske standarder.