Hifair™ III Reverse Transcriptase, 600 U/μL, Glycerol-free _ 11297ES

YeasenSKU: 11297ES09

Size: 6 KU
Harga:
Harga penjualan$185.00

Pengiriman dihitung saat pembayaran

Saham:
Dalam stok

Keterangan

Hifair™ III Reverse Transcriptase is a novel reverse transcriptase engineered from Hieff™ M-MLV (H-) Reverse Transcriptase. Compared to its predecessor, Hifair™ III exhibits significantly enhanced thermostability, tolerating reaction temperatures of up to 65°C, making it ideal for reverse transcribing RNA templates with complex secondary structures. Additionally, this enzyme features increased template affinity, making it highly suitable for reverse transcription of limited samples and low-copy genes. Its ability to synthesize full-length cDNA has also been improved, capable of extending cDNA up to 19.8 kb. This glycerol-free version (600 U/μL) is specifically designed for the preparation of lyophilized formulations and lyophilizable RT-LAMP reagents.

Specifications

Cat.No.

11297ES09 / 11297ES12 / 11297ES75

Size

6 KU / 12 KU / 300 KU

Components

Components No.

Name

11297ES09 
(6 KU)

11297ES12
(12 KU)

11297ES75 (300 KU)

11297

Hifair™ III Reverse Transcriptase (600 U/µL, Glycerol-free)

10 μL

20 μL

500 μL

Storage

This product should be stored at 2~8℃ for 6 months.

Applications

Preparation of lyophilized formulations

Lyophilizable RT-LAMP kits 

Activity Definition

One unit (U) is defined as the amount of enzyme required to incorporate 1 nmol of dTTP into acid-insoluble material using Poly(A)·Oligo(dT) as the template-primer in 10 minutes at 37°C.

Notes

1. This product is for research use only.

2. Please operate with lab coats and disposable glovesfor your safety. 
3. Maintain a clean experimental area. Wear clean gloves and a mask during operation. Ensure all consumables are RNase-free to prevent RNase contamination.

4. Perform all operations on ice to prevent RNA degradation.

5. High-quality RNA samples are recommended to ensure efficient reverse transcription.

Instructions

1. Reaction System Setup

Cat. No.

Component

Volume

13840-A

10×Bst Buffer

2.5 µL

13840-C

100 mmol/L MgSO4

2 µL

dNTP Mix (100 mmol/L)

dNTP Mix (100 mmol/L)

3.5 µL

dUTP Mix (100 mmol/L)(Optional)

dUTP Mix (100 mmol/L)(Optional)

0.35 µL

11297

Hifair™ III Reverse Transcriptase (600 U/µL, Glycerol-free)

0.1 µL

10703

Murine RNase inhibitor (200 U/µL, Glycerol-free)

0.2 µL

13839(Optional)

Heat Labile UDG (200 U/µL)(Optional)

0.005 µL

10×Primersa

10×Primers

2 µL

13840-Bb

Bst Ⅱ Plus DNA polymerase (120 U/µL, Glycerol-free)

0.5 µL

RNase free ddH2O

RNase free ddH2O

To 25 µL

[Note]:

a. 10× Primers: 16 µmol/L FIP/BIP, 2 µmol/L F3/B3, 4 µmol/L Loop F/B each. The primer ratios can be adjusted as needed.

b. Volumes can be adjusted according to specific experimental conditions.

2. Reaction Program Settings:

Temperature

Time

Function

37℃

2 min

Digestion

65℃

30-60 mina

Reverse Transcription and Isothermal Amplification

85℃

10 min

Enzyme Inactivation

[Note]:

a. For probe-based methods, fluorescence can be collected directly in the target channel at 1-minute intervals. For dye-based methods, you may additionally add Dye (Cat# 13841), select the SYBR channel, and collect fluorescence at 1-minute intervals.

Documents:

Safety Data Sheet

11297_MSDS_HB260630

Manuals

11297_Manual_HB20260630

Pembayaran & Keamanan

American Express Apple Pay Diners Club Discover Google Pay Mastercard Visa

Informasi pembayaran Anda diproses dengan aman. Kami tidak menyimpan detail kartu kredit atau memiliki akses ke informasi kartu kredit Anda.

Anda mungkin juga menyukai

Pertanyaan

FAQ

Produk ini hanya untuk keperluan penelitian dan tidak ditujukan untuk penggunaan terapeutik atau diagnostik pada manusia atau hewan. Produk dan konten dilindungi oleh paten, merek dagang, dan hak cipta milik Yeasen Bioteknologi. Simbol merek dagang menunjukkan negara asal, belum tentu pendaftaran di semua wilayah.

Aplikasi tertentu mungkin memerlukan hak kekayaan intelektual pihak ketiga tambahan.

Yeasen didedikasikan untuk ilmu etika, meyakini penelitian kami harus menjawab pertanyaan kritis sambil memastikan standar keselamatan dan etika.