विवरण
Hieff UniconTM Universal Superfast qPCR Mix (One Tube) is a fluorescent quantitative qPCR premix that employs the company's new-generation antibody-mediated hot-start Taq DNA polymerase. This product features broad applicability, supports fast protocols, and comes in a fully pre-mixed format.
Features
- Supports fast protocols: Results available in as little as 20 minutes.
- Excellent premix stability: Stable after 7 days at 37°C and 20 freeze-thaw cycles.
- Low-DNA residue: No detectable residual DNA from E. coli, P. aeruginosa, or human genomic DNA across 48 wells.
- Broad reagent compatibility: Compatible with over 40 types of multiplex primers/probes; consistently delivers stable amplification.
- High sensitivity and specificity: Detects as low as 200 copies/mL; no false positives in 48 negative samples.
- dUTP/UDG anti-contamination system: Incorporates a dUTP/UDG system to effectively prevent aerosol contamination.
- Compatible with multiple platforms and systems: Validated on Bio-Rad CFX96, ABI Q5, 7500, SLAN, etc.
Components
Name |
16924ES60 (100 T) |
16924ES80 (1000 T) |
16924ES92 (10000T) |
2×Superfast qPCR mix |
1.25 mL |
12.5 mL |
125 mL |
Storage
This product should be stored at -25~-15℃ for 1 year.
Application
- Urgent testing (e.g., Infectious disease detection, Critical care diagnostics);
- High-throughput testing(e.g., Disease screening, Pathogen screening, Virus detection);
- Routine testin(e.g., Food microbiology detection ).
Figures
1. Excellent Amplification Performance Across qPCR Platforms

Figure 1. Amplification efficiency test of N. meningitidis and S. pneumoniae using fast cycling protocols.
(A) ABI 7500 Fast Mode: N. meningitidis (R² = 0.999, Eff = 99.864%), S. pneumoniae (R² = 1.000, Eff = 98.952%)
(B) ABI Q5 Fast Mode: N. meningitidis (R² = 0.999, Eff = 99.14%), S. pneumoniae (R² = 1.000, Eff = 99.756%)
2. Superior Amplification Performance Under Fast vs. Conventional qPCR Programs
Instrument |
SLAN |
System |
5 μL DNA(25 μL total volume) |
Template |
bacterial plasmid template (B-tube and P-tube). |
Template concentrations |
Ct 30-35 |
Progarm |
Conventional program (96S/48S): 95°C 5 min;40 cycles (95°C 15sec;60°C 30 sec)--50 min Fast program (48S Fast): 95°C 15 sec;40 cycles (95°C 2sec;60°C 8 sec)--20 min |
Table 1. Sensitivity Evaluation of 16924 Under Fast and Conventional Programs
16924 |
Group B |
Group P |
||||||
fluorescence channel |
FAM |
VIC |
ROX |
FAM |
VIC |
CY5 |
ROX |
|
96S-Conventional program |
Mean Ct Value |
36.16 |
36.13 |
33.23 |
35.61 |
38.81 |
NA |
36.03 |
Detection Rate |
16/16 |
16/16 |
16/16 |
12/16 |
13/16 |
0 |
15/16 |
|
fluorescence channel |
FAM |
VIC |
ROX |
FAM |
VIC |
CY5 |
ROX |
|
48S-Fast program |
Mean Ct Value |
36.54 |
36.31 |
33.54 |
36.46 |
39.14 |
36.87 |
36.31 |
Detection Rate |
16/16 |
16/16 |
16/16 |
14/16 |
11/16 |
2/16 |
13/16 |
|
fluorescence channel |
FAM |
VIC |
ROX |
FAM |
VIC |
CY5 |
ROX |
|
48S-Conventional program |
Mean Ct Value |
36.30 |
36.34 |
33.77 |
35.54 |
38.73 |
39.41 |
35.58 |
Detection Rate |
16/16 |
16/16 |
16/16 |
14/16 |
9/16 |
10/16 |
14/16 |
Figure 2. Performance comparison of 16924 and Supplier A* using conventional and fast programs.
Two sets of 4-plex plasmid templates (B-tube and P-tube) were tested using both 16924 and Supplier A* at relatively high template concentrations (Ct 30–35). Supplier A* showed over 1 cycle delay in Ct values under the fast program for P-tube templates, while 16924 showed no significant difference between programs. Some targets in 16924 amplified earlier in the fast protocol.
3. Strong stability

Figure 3. Stability testing of 16924 premix using ASFV nucleic acids extracted from real samples (singleplex).
Thermal accelerated stability testing was performed by incubating the 16924 premix mixed with primers and probes at 37°C for 7 days. qPCR conditions: 95°C for 90 sec; 45 cycles of 95°C for 5 sec and 55°C for 30 sec. The results demonstrate that the premix maintained stable performance with consistent Ct values and amplification curves after incubation, indicating excellent thermal stability.
4. High inhibitor tolerance

Figure 4. Comparative performance of 16924 and a commercial product (Supplier A) using 4-plex plasmid templates diluted in different buffers.
Templates diluted in various solutions, including TE buffer and saline, were tested with 16924 and Supplier A*. The results show that 16924 exhibits greater tolerance to diverse dilution buffers—particularly saline—providing more reliable detection in buffer-restricted or field-based settings.
Documents:
Safety Data Sheet
Manuals
16924_Manual_Ver.EN20250801.pdf
Related Blog
भुगतान और सुरक्षा
आपकी भुगतान जानकारी सुरक्षित रूप से संसाधित की जाती है। हम क्रेडिट कार्ड के विवरण को संग्रहीत नहीं करते हैं और न ही आपके क्रेडिट कार्ड की जानकारी तक पहुंच है।
जाँच करना
आपको यह भी पसंद आ सकता हैं
उपवास
यह उत्पाद केवल शोध उद्देश्यों के लिए है और मनुष्यों या जानवरों में चिकित्सीय या नैदानिक उपयोग के लिए अभिप्रेत नहीं है। उत्पाद और सामग्री येसेन बायोटेक्नोलॉजी के स्वामित्व वाले पेटेंट, ट्रेडमार्क और कॉपीराइट द्वारा संरक्षित हैं। ट्रेडमार्क प्रतीक मूल देश को इंगित करते हैं, जरूरी नहीं कि सभी क्षेत्रों में पंजीकरण हो।
कुछ अनुप्रयोगों के लिए अतिरिक्त तृतीय-पक्ष बौद्धिक संपदा अधिकारों की आवश्यकता हो सकती है।
येसेन नैतिक विज्ञान के प्रति समर्पित हैं, उनका मानना है कि हमारे शोध में सुरक्षा और नैतिक मानकों को सुनिश्चित करते हुए महत्वपूर्ण प्रश्नों का समाधान किया जाना चाहिए।