Описание
This product is a lyophilized micro-core (primers and probes not included) prepared from the liquid lyo-ready formulation of the Hifair™ Lyo-Ready Multiplex One Step RT-qPCR Kit (UDG plus)(Cat#16645ES). It enables multiplex quantitative PCR reactions using RNA as a template. By combining reverse transcription and quantitative PCR in a single reaction tube, this kit simplifies experimental procedures and minimizes the risk of contamination.
Utilizing advanced lyophilization technology, this product transforms liquid reagents into stable lyophilized micro-cores. This design significantly facilitates storage and transportation while enhancing the overall stability of the reagents.
Features
- Broad Compatibility: Suitable for direct detection or freeze-dried for long-term storage
- Strong stability: after freeze-drying, the stability is still good at 50℃ for 25 days
- Support fast program: the fastest 40 minutes to get the result
- Significant anti-pollution effect: UDG/dUTP anti-pollution system, easy to remove contamination.
Application
Virus detection; pathogen detection; gene expression analysis
Specifications
|
Cat.No. |
16936ES16 / 16936ES96 |
|
Size |
16 T / 96 T |
Components
|
Components No. |
Name |
16936ES16 |
16936ES96 |
|
16936 |
8-Strip Lyophilized Micro-core |
16 Units |
96 Units |
Storage
This product should be stored at -25~-15℃ for one year.
Figures
1. Freeze-dried products form
Figure 1. Freeze-dried product form(Eight-row freeze-dried micropheres)
2. Consistent performance

Figure 2. Consistent performance between Liquid reagent and lyophilized Microspheres
3. Stability test—Appearance stability of freeze-dried microspheres
Figure 3. Freeze-dried microspheres accelerate stability((fast procedure)
After being freeze-dried into freeze-dried microspheres using Yeasen's RNA lyophilizable reagent (Catt#16936ES), placed under different conditions (accelerated at 50°C for 33 days), and 104, and 103 copies/mL of HPIV pseudovirus templates were amplified simultaneously. The results showed that there was no significant change in the Ct value, fluorescence value, spherical shape, etc. of the freeze-dried microspheres before and after thermal acceleration, and the freeze-dried product had good stability.
4. Mutiplex PCR Amplification of pathogens

Figure 4. Multiplex amplification of pathogens
(HPIVs, Template concentration E6/5/4/3/2/1)
Documents:
Safety Data Sheet
Manuals
Оплата и безопасность
Ваша платежная информация обрабатывается надежно. Мы не храним данные кредитной карты и не имеем доступа к информации вашей кредитной карты.
Вам также может понравиться
Расследование
Часто задаваемые вопросы
Продукт предназначен только для исследовательских целей и не предназначен для терапевтического или диагностического использования на людях или животных. Продукты и содержимое защищены патентами, товарными знаками и авторскими правами, принадлежащими Yeasen Biotechnology. Символы товарных знаков указывают на страну происхождения, а не обязательно на регистрацию во всех регионах.
Для некоторых приложений могут потребоваться дополнительные права интеллектуальной собственности третьих лиц.
Йесен привержен этической науке, полагая, что наши исследования должны затрагивать важнейшие вопросы, обеспечивая при этом безопасность и соблюдение этических стандартов.