E.coli Host Cell RNA Residue Detection Kit _ 41318ES

YeasenSKU: 41318ES50

Size: 50 T
Prijs:
Verkoopprijs$1,905.00

Verzendkosten berekend bij het afrekenen

Voorraad:
Op voorraad

Beschrijving

E.coli Host Cell RNA Residue Detection Kit is used for the quantitative analysis of E.coli host cell RNA residuce in intermediate samples, semi-finished and finished products of various biological products.

This kit adopts Taqman fluorescent probe and the polymerase chain reaction (PCR) method, which has fg level minimum detection limit and can specifically and quickly detect the residual E.coli cell RNA. The kit needs to be used together with the the Residual DNA Sample Preparation Kit (Cat# 18461ES) and Recombinant DNase I (RNase-free, Yeast) (Cat#14534ES50/14534ES60).

Feature

  • Compliance with regulations: the products are fully validated according to the requirements of Chp, USP, ICH, etc., and their performance is in line with Chinese and foreign regulations and standards;
  • Guarantee of quality: the raw materials of the kits are all self-developed, and the qPCR Mix and other enzyme products are produced in an ultra-clean enzyme factory;
  • High sensitivity: the limit of quantification can reach 1 fg/μL level;
  • High precision: high intra-batch repeatability and low inter-batch variation;
  • Strong exclusivity: specific detection of residual RNA in E.coli cells without interference from other exogenous genomic DNA and RNA;
  • Strong anti-interference: add internal control (IC), easy to exclude sample interference, reaction preparation abnormalities and other factors.

Application

  • Residual E.coli Host Cell RNA test in biological products.

Specification

Sensitivity

1 fg/μL (range 2fg/μL~200pg/μL)

Assay Time

~1.5 hours

Assay Principle

Fluorescent probe qPCR method

Required Instruments

Real-time fluorescence quantitative PCR system

Components

Components No.

Name

41318ES50-EN

41318ES60-EN

41318-A

E.coli qPCR Mix

0.75 mL

1.5 mL

41318-B

One Step Enzyme Mix

200 μL

400 μL

41318-C

RNA Dilution Buffer

1.8 mL×2

1.8 mL×4

41318-D

E.coli RNA Control20 ng/μL

25 μL

50 μL

41318-E

IC*

50 μL

100 μL

*ICInternal control.

Storage

This product should be stored at -25~-15℃ for 2 years.

Both 41318-A should be stored protected from light.

Figures

  • Limit of quantification

E.coli RNA was detected at 5 fg/uL, 2 fg/uL, and 1 fg/uL, with 10 replicates for each concentration. The results showed that the CV was <20% at concentrations of 1 fg/uL and above, i.e., the limit of quantification of the E.coli host cell RNA residue detection kit was 1 fg/uL.

 Table 1. Limit of quantification (LOQ) assay results for E.coli RNA

 

Repetition number

Test item

E.coli RNA (fg/uL)

Quantity

Return ratio

1

0.98

98%

2

1.00

100%

3

1.37

137%

4

0.97

97%

5

0.97

97%

6

1.02

102%

7

0.98

98%

8

1.06

106%

9

1.08

108%

10

1.03

103%

Average value

1.05

\

CV%

11.44%

\

 

 

 

Documents:

Safety Data Sheet

41318_MSDS-HB250224.PDF

Manuals

41318_Manual-Ver.EN20250224.PDF

Betaling en beveiliging

American Express Apple Pay Diners Club Discover Google Pay Mastercard Visa

Uw betalingsinformatie wordt veilig verwerkt. We slaan geen creditcardgegevens op en hebben geen toegang tot uw creditcardinformatie.

Navraag

Misschien vind je het ook leuk

FAQ

Het product is alleen bedoeld voor onderzoeksdoeleinden en is niet bedoeld voor therapeutisch of diagnostisch gebruik bij mensen of dieren. Producten en inhoud worden beschermd door patenten, handelsmerken en auteursrechten die eigendom zijn van Yeasen Biotechnologie. Handelsmerksymbolen geven het land van herkomst aan, niet noodzakelijkerwijs registratie in alle regio's.

Voor bepaalde toepassingen zijn mogelijk aanvullende intellectuele eigendomsrechten van derden vereist.

Yeasen is toegewijd aan ethische wetenschap en is van mening dat ons onderzoek kritische vragen moet beantwoorden en tegelijkertijd de veiligheid en ethische normen moet waarborgen.