설명
ATP is the main energy molecule in cells and closely reflects metabolic activity. Since ATP levels are proportional to the number of viable cells, measuring ATP provides a reliable way to assess cell viability.
This kit uses Firefly luciferase, which catalyzes the reaction of luciferin with ATP and O₂ in the presence of Mg²⁺, producing light. The luminescence intensity is directly proportional to ATP concentration, and therefore to the number of viable cells.
The assay is highly sensitive, stable, and easy to use. In a 96-well format, it shows a strong linear response from 5 to 100,000 cells per well (the upper limit may vary by cell type). The procedure is fast—results are obtained in about 10 minutes—with no need for washing or medium replacement. The reagent has a long half-life and excellent stability. Compared with Calcein-AM and CCK-8 assays, the ATP-based method is simpler, faster, and more efficient.
Features
- Wide Linear Range: Shows good linearity from 100 to 20,000 cells per well in a 96-well plate, though the upper detection limit may vary slightly between cell types.
- Easy to Use: Simple protocol with ready-to-use reagents. No cell washing or medium removal required. Fast detection—results in about 10 minutes with stable readings.
- Excellent Stability: Reagents have a half-life of up to 3 hours. They remain over 90% active after 30 days at room temperature or 60 days at 2–8 °C.
Components
Components No. |
Name |
40211ES10 |
40211ES60 |
40211ES70 |
40211 |
ATP Luminescent Cell Viability Assay Kit 2.0 |
10 mL |
100 mL |
10x100 mL |
Shipping and Storage
This product should be stored at -25~-15℃ for 1 year.
Application
- Cell proliferation and cytotoxicity evaluation
- High-throughput drug screening
- Apoptosis and cell death detection
- Metabolic activity analysis
- Toxicology and safety assessment
Figures
1. Good linearity

Figure 1. Excellent Linearity of ATP-Based Luminescent Assay within 100,000 Cells
The ATP Luminescent Cell Viability Assay Kit shows a strong linear correlation between luminescence intensity and cell number, maintaining good linearity up to 1 × 10⁵ cells per well.
2. Signal Stability Analysis
![]() |
![]() |
Figure 2. Signal Stability Analysis within 300 Minutes
3. Strong Stability
![]() |
![]() |
Figure 3. Stability Test
40211ES remains stable after up to 10 freeze-thaw cycles. Stability at 4 °C is maintained for up to 2 months, and at room temperature for up to 1 month-—significantly outperforming company P and V.
Documents:
Safety Data Sheet
Manuals
40211_Manual_Ver.EN20250820.pdf
Related Blog
New Arrival: ATP Vitality Detection Kit with More Stable Signal
결제 및 보안
귀하의 결제 정보는 안전하게 처리됩니다. 당사는 신용카드 정보를 저장하지 않으며 귀하의 신용카드 정보에 접근할 수 없습니다.
문의
당신은 또한 좋아할 수 있습니다
자주 묻는 질문
이 제품은 연구 목적으로만 사용되며 인간이나 동물의 치료 또는 진단용으로 의도되지 않았습니다. 제품과 콘텐츠는
특정 애플리케이션에는 추가적인 제3자 지적 재산권이 필요할 수 있습니다.
예슨은 윤리적 과학에 헌신하며, 우리의 연구가 안전과 윤리적 기준을 보장하는 동시에 중요한 문제를 해결해야 한다고 믿습니다.