Hieff NGS™ MaxUp Human/Mouse/Rat rRNA Depletion Kit(rRNA ITS/ETS) 2.0 _ 12726ES

Yeasen제품번호: 12726ES12

Size: 12 T
가격:
판매 가격$455.00
재고:
재고 있음

Hieff NGS™ MaxUp Human/Mouse/Rat rRNA Depletion Kit (rRNA & ITS/ETS) 2.0 utilizes an RNase H digestion method to remove ribosomal RNA (rRNA) and the 45S & ITS/ETS regions from total RNA isolated from human, mouse, and rat samples, thereby enriching messenger RNA (mRNA) and other non-coding RNAs. This kit effectively removes rRNA from both intact and partially degraded total RNA (such as FFPE-derived RNA). Since degraded FFPE samples typically contain a higher proportion of ITS/ETS fragments compared to fresh tissue samples, the inclusion of specific probes targeting the human, mouse, and rat 45S & ITS/ETS regions in this kit significantly increases the proportion of usable sequencing data after depletion.

Features

Strong Specificity: Efficiently removes rRNA as well as ITS/ETS regions from human samples, with excellent performance on challenging FFPE samples.

Broad Input Compatibility: Suitable for a wide range of input amounts (100 ng to 1 μg).

High Removal Efficiency: Achieves >95% removal of rRNA, ITS, and ETS from human, mouse, and rat samples.

Consistent Quality: Strict batch-to-batch performance and stability controls ensure reliable results.

Components

Components No.

Name

12726ES12

12726ES24

12726ES96

12726-A

Hybridization Buffer

36 μL

72 μL

288 μL

12726-B

Human Probe Mix (rRNA & ITS/ETS)

24 μL

48 μL

192 μL

12726-C

RNase H Buffer

36 μL

72 μL

288 μL

12726-D

Thermostable RNase H

4 μL

48 μL

192 μL

2726-E

DNase I Buffer

330 μL

660 μL

2x1320 μL

12726-F

DNase l

30 μL

60 μL

240 μL

Applications

Gene Expression Research

Alternative splicing analysis

Detection and discovery of LncRNA(Non coding RNA)

dentification of selective polyadenylation sites

Fusion gene detection

Figures

1. Broad Compatibility Across Input Amounts and Sample Types

Figure 1. Superior rRNA Removal Efficiency Across a Broad Input Range

Figure 1. Superior rRNA Removal Efficiency Across a Broad Input Range

Library preparation was performed using the MaxUp™ rRNA Depletion Kit and a strand-specific RNA Library Preparation Kit on human, mouse, and rat total RNA samples. Unlike traditional kits limited to 1 µg input, MaxUp™ demonstrates consistent and efficient rRNA removal across a wide range of input amounts (100 ng to 1 µg), achieving <1% rRNA residual.

2. Effective rRNA Removal

&nbsp;Figure 2. Comparison of rRNA Removal Efficiency: Depletion vs. Enrichment

Figure 2. Comparison of rRNA Removal Efficiency: Depletion vs. Enrichment

Using 1 μg of 293T total RNA, samples were processed using either oligo-dT enrichment or rRNA depletion methods. Sequencing analysis revealed that both methods achieved comparable levels of rRNA removal efficiency.

3. Optimized for FFPOptimized for FFPE & Degraded Samples

Figure 3. Robust rRNA Depletion Performance in FFPE Samples Across a Wide DV200 Range

Figure 3. Robust rRNA Depletion Performance in FFPE Samples Across a Wide DV200 Range

MaxUp™ is optimized for challenging FFPE RNA, maintaining strong performance even with degraded transcripts. The kit demonstrates consistent and efficient rRNA removal across a broad DV200 range (20%–70%), achieving >98% depletion efficiency with a 100 ng input. This ensures high-quality, low-background library construction, making it highly compatible with low-quality samples (DV200 < 50%) for clinical and archival tissue research.

4. Automation-Ready Stability

Figure 4. Enhanced Stability and Automation Compatibility&nbsp;

Figure 4. Enhanced Stability and Automation Compatibility

MaxUp™ features a stabilized RNase H system that eliminates the need for fresh enzyme preparation, making it ideal for automated, high-throughput workflows. The kit maintains superior depletion efficiency (>95%) under various storage conditions, including extended periods at 37°C, RT, and 4°C.

Storage

This product should be stored at -25~-15℃ for 12 months.

FAQ

Citations

당신은 또한 좋아할 수 있습니다

문의

자주 묻는 질문

이 제품은 연구 목적으로만 사용되며 인간이나 동물의 치료 또는 진단용으로 의도되지 않았습니다. 제품과 콘텐츠는 Yeasen Biotechnology가 소유한 특허, 상표 및 저작권으로 보호됩니다. 상표 기호는 모든 지역에서 반드시 등록되는 것은 아니지만 원산지를 나타냅니다.

특정 애플리케이션에는 추가적인 제3자 지적 재산권이 필요할 수 있습니다.

예슨은 윤리적 과학에 헌신하며, 우리의 연구가 안전과 윤리적 기준을 보장하는 동시에 중요한 문제를 해결해야 한다고 믿습니다.