Hieff Canace™ Veritas High Fidelity Long PCR Master Mix (With Dye) _ 10166ES

YeasenSKU: 10166ES01

Size: 250 μL
سعر:
سعر البيع$20.00
مخزون:
في الأوراق المالية

Hieff Canace™ Long PCR Master Mix (With Dye) is a ready-to-use 2× pre-mixed solution containing Hieff Canace™ High-Fidelity DNA Polymerase, dNTPs, and an optimized buffer system, which contains pre-added electrophoresis indicators. The pre-mix contains pre-added electrophoresis indicator, PCR products can be directly electrophoresed, the amplification products are flat ends. 2× Hieff Canace™ Long PCR Master Mix (With Dye) has the advantages of quick and easy, high sensitivity, high specificity, good stability, etc., the reaction system can be added with only the primers and templates. In addition, the product also contains a specific protective agent, so that the premix can still maintain stable activity after repeated freezing and thawing.

Ultra-high fidelity: Low mismatch rate in mutation-prone high GC gene;
Fast speed: The speed is as fast as 5 sec/kb;
Wide applicability: It can be used to amplify genes with 20-80% GC content, and tolerate 20% blood and mouse lysates;
Good stability: Stored at 37°C for 7 days without affecting performance;
Easy use: Just adding primers and templates for amplification, with blue loading dye for direct electrophoresis.

Specifications

Cat NO.

10166ES01 / 10166ES03 / 10166ES08 / 10166ES25 / 10166ES30

Size

250 μL / 1 mL / 5×1 mL / 25×1 mL / 25 mL

Components

Name

10166ES01

10166ES03

10166ES08

10166ES25

10166ES30

Hieff Canace™ Veritas Long PCR Master Mix (With Dye)

250 μL

1 mL

5×1 mL

25×1 mL

25 mL

Figures

Figure1. High sensitivity of Hieff Canace™ High-Fidelity Long PCR Master Mix.


Figure 2. Long PCR from cDNA by Hieff Canace™ High-Fidelity Long PCR Master Mix.

Notes

  1. This product is for research use only.
  2. Please operate with lab coats and disposable gloves,for your safety.

Storage

This product should be stored at -25~-15℃ for 1 years.

FAQ

When dealing with fragments larger than 10 kb, it is advisable to combine 68℃ with 10 sec/kb to enhance the amplification success rate. For fragments smaller than 10 kb, an amplification speed of 5 sec/kb can be used.
(1) This 10166ES product can accommodate cDNA amplification ranging from 1 kb to 14 kb. If you need to perform long fragment amplification, it is recommended to use the validated 11149ES reverse transcription kit from Yeasen Biotechnology to reverse transcribe the target RNA. The resulting cDNA template can then be used in conjunction with 10166ES for long fragment amplification.
(2) If the RNA sample is small or if you need to obtain a very long target fragment, it is recommended not to perform digestion during reverse transcription. The longer the target fragment, the more RNA needs to be input, and accordingly, more cDNA will be required.
10166ES is a high-fidelity PCR product. High fidelity means a lower error rate and more accurate sequences. However, different experimental methods may result in variations. Product mutations are low-probability events. It is recommended to perform multiple repeated sets of new amplifications to obtain unmutated amplification products.
Yes, after testing, the 10166ES can cover fragments with GC content ranging from 20% to 80%. When expanding fragments with a high GC content, it is recommended to adjust the temperature to 68℃, which will significantly increase the success rate.
The 10166ES can tolerate a certain amount of bacterial solution. After testing, it has been found that this product can tolerate bacterial solution at a proportion of 12.5% in the reaction system, and it has good specificity. If you need to directly expand the bacterial solution, please keep the proportion below 12.5%.
The 10166ES product can tolerate a certain amount of cDNA stock solution, which contains residual RNA and degraded RNA. Therefore, cDNA containing uracil can be used as the template. However, there is a certain range. After product performance testing, 10166ES can meet the requirement of a cDNA input volume accounting for 15% of the reaction system.
(1) For plant genomes, after product performance testing, it can detect as low as 100pg of plant genome.
(2) For animal genomes, after product performance testing, the minimum detectable amount is 100pg of animal genome.
(3) For plasmids, since they are relatively pure, after product performance testing, the minimum detectable amount is 1pg of plasmid.
Possible causes and solutions:
(1)The thawing requirements for 10166ES stipulate that it should be thawed slowly on ice, and it cannot be thawed at room temperature or through heating.
(2) When performing the amplification process, it is recommended to set the temperature at 68℃ and the amplification speed at 10 seconds per kilobase.
(3) The longer the target fragment to be amplified is, the more template should be used.
(4) In the PCR system, the concentration of primers is too low or the number of cycles is insufficient: appropriately increase the amount of primers, or increase the number of amplification cycles;

Citations

Applications

You may also like

Inquiry

FAQ

The product is for research purposes only and is not intended for therapeutic or diagnostic use in humans or animals. Products and content are protected by patents, trademarks, and copyrights owned by Yeasen Biotechnology. Trademark symbols indicate the country of origin, not necessarily registration in all regions.

Certain applications may require additional third-party intellectual property rights.

Yeasen is dedicated to ethical science, believing our research should address critical questions while ensuring safety and ethical standards.