Sự miêu tả
Hieff NGS™ Full UDI Adapter Kit for Illumina is an adapter kit specifically designed for library preparation on Illumina high-throughput sequencing platforms. The kit contains UDI adapters used for next-generation sequencing (NGS) library preparation. Cat#12333–12336 are provided in plate format (Set1/Set2/Set3/Set4). Each set contains 96 adapters, enabling the construction of up to 384 uniquely dual-indexed libraries.
All reagents included in the kit have undergone strict quality control and functional validation to ensure the stability and reproducibility of library preparation to the greatest extent.
Specifications
|
Cat.No. |
12333ES01 / 12333ES02 |
|
Size |
96×1 T / 96×2 T |
Components
|
Components No. |
Name |
12333ES01 (96×1 T) |
12333ES02 (96×2 T) |
|
12333 |
UDI Adapter 001-096 |
5 μL each |
10 μL each |
Storage
This product should be stored at -25~-15℃ for 2 years.
Notes
1. The concentration of the UDI adapters in this kit is 10 μM. The amount of adapter used for each library preparation should be adjusted according to the requirements of the library preparation kit being used.
2. Do not heat the adapters. Allow them to dissolve slowly at room temperature. The laboratory temperature is recommended to be maintained at 20–25°C. Avoid repeated freeze–thaw cycles. It is recommended to aliquot the adapters for storage, and they may be stored at 4°C for short-term use.
3. The structure of the DNA library constructed using the Hieff NGS™ Full UDI Adapter Kit for Illumina is shown below.

4. For your safety and health, please wear a lab coat and disposable gloves when performing the experiment.
5. This product is for research use only.
Sequence Information
UDI Adapter for Illumina:
i5 Index for Illumina:
5´-AATGATACGGCGACCACCGAGATCTACAC[i5 Index]ACACTCTTTCCCTACACGACGCTCTTCCGATC*T-3´
i7 Index for Illumina:
5´-/5Phos/GATCGGAAGAGCACACGTCTGAACTCCAGTCAC[i7 Index]ATCTCGTATGCCGTCTTCTGCTT*G-3´
The notation [i5 Index] denotes an 8-bp i5 index sequence, and [i7 Index] denotes an 8-bp i7 index sequence.
The corresponding positions of each adapter in the 96-well plate are shown in the figure below.

Documents
Safety Data Sheet
Manuals
Thanh toán & Bảo mật
Thông tin thanh toán của bạn được xử lý an toàn. Chúng tôi không lưu trữ chi tiết thẻ tín dụng cũng như không có quyền truy cập vào thông tin thẻ tín dụng của bạn.
Bạn cũng có thể thích
Cuộc điều tra
Câu hỏi thường gặp
Sản phẩm chỉ dành cho mục đích nghiên cứu và không dùng để điều trị hoặc chẩn đoán ở người hoặc động vật. Sản phẩm và nội dung được bảo vệ bởi các bằng sáng chế, nhãn hiệu và bản quyền thuộc sở hữu của
Một số ứng dụng có thể yêu cầu thêm quyền sở hữu trí tuệ của bên thứ ba.