NGS can generate enormous amounts of sequencing data, but as sample numbers increase, one part of the workflow often becomes a bottleneck: library preparation.

A workflow that works well for 8 or 24 samples may become much harder to manage at 96 samples or beyond. More pipetting means more hands-on time, more opportunities for variation, and greater pressure on laboratory staff.

This is where automation can make a difference.

But successful NGS automation is about more than putting a liquid handler on the bench. The real goal is to build a library preparation workflow that is scalable, consistent, and practical to run routinely.

Why Library Preparation Matters

Library preparation converts DNA or RNA samples into sequencing-ready libraries through steps such as:

  • Fragmentation
  • End repair and A-tailing
  • Adapter ligation
  • Bead-based purification
  • Reverse transcription for RNA workflows
  • PCR amplification
  • Library quantification and QC

Each step can affect the final library.

Poor library preparation can contribute to insufficient yield, uneven coverage, unwanted fragments, or inconsistent sequencing results. For this reason, high-quality sequencing starts with a well-controlled library preparation workflow.   

When Does Manual Library Prep Become a Bottleneck?

Manual preparation can work well for small-scale projects. The challenges become more obvious as throughput increases.

Challenge

What happens as throughput increases?

Repetitive pipetting

Dozens of liquid-handling steps quickly add up across 96 samples

Hands-on time

More samples require more labor or longer working hours

Operator variation

Pipetting, mixing, bead handling, and timing can introduce variability

Batch consistency

Maintaining comparable performance across operators and runs becomes harder

Reagent consumption

Manual handling can increase overage and unnecessary reagent use

What Does NGS Automation Actually Change?

The value of automation goes beyond reducing pipetting.

A well-designed automated workflow can provide:

  • Standardization — programmed liquid handling and incubation steps reduce operator-dependent variation.
  • Throughput — larger batches can be processed without increasing hands-on labor proportionally.
  • Traceability — automated run records make workflows easier to monitor and document.
  • Reproducibility — standardized parameters help maintain consistency across batches.

For high-throughput laboratories, these benefits can be more important than simply saving a few hours of hands-on work.

Figure 1. Manual versus automated library preparation: the automation dividend. 

Figure 1. Manual versus automated library preparation: the automation dividend.

The Automated Workflow

Automation covers all pipetting, mixing, incubation and purification operations of library construction; the exact flow depends on the sample type. DNA and RNA routes share the same backbone — RNA simply adds enrichment and reverse transcription before the DNA steps.

Figure 2. Automated DNA and RNA library-preparation routes on the MGISP-960. 

Figure 2. Automated DNA and RNA library-preparation routes on the MGISP-960.

What Should You Evaluate Before Choosing an Automated Workstation?

Choosing an automation system should start with the workflow, not just the instrument specifications.

1. Throughput

How many samples do you process per run, per day, or per week?

A 96-sample system may be sufficient for one laboratory but limiting for another. Consider whether the platform can support future growth without a proportional increase in labor.

2. Application Coverage

Will the system support only your current workflow, or can it adapt to future applications? A flexible automation platform can be more valuable than a system optimized for only one application.

Application

Example workflow

DNA sequencing

WGS, targeted sequencing, cfDNA, FFPE

RNA sequencing

mRNA-seq, total RNA-seq

Microbial sequencing

mNGS, targeted sequencing

Epigenomics

Methylation sequencing

Single-cell

Single-cell library preparation

Long-read sequencing

Long-read library preparation

3. Reagent Compatibility

Automation-friendly reagent formats can simplify liquid handling and reduce unnecessary manual transfers.

Premixed reagents, plate-based formats, optimized working volumes, and appropriate dead-volume considerations can all improve workflow efficiency.

4. Script Validation and Support

A demonstration script is not necessarily a validated workflow.

Before choosing a system, consider:

  • Who develops and validates the scripts?
  • Can workflows be customized?
  • How are protocol updates handled?
  • What support is available after installation?

For many laboratories, ongoing application support is just as important as the instrument itself.

5. Total Cost of Ownership

Instrument price is only one part of the equation.

Labor, reagents, consumables, maintenance, and workflow development all contribute to the long-term cost.

Instead of asking only:

“How much does the instrument cost?”

consider:

“What does it cost to run this workflow at the throughput I need?”

Making Automation Work in the Real Laboratory

Successful automation depends on details beyond the instrument.

  • Before the run

Define the library type, sample number, input range, sequencing platform, reagent compatibility, and pre-/post-PCR workflow layout.

  • During the run

Standardize liquid classes, plate formats, bead handling, mixing, incubation, and pipetting parameters.

  • After the run

Track library yield, fragment size, QC results, and run records consistently.

This turns automation from a liquid-handling tool into a controlled and traceable library preparation workflow.

Think Beyond the Instrument

For laboratories moving toward automation, it can be useful to think about the workflow in four layers:

Instrument → Reagents → Validated Workflows → Application Support

Each layer matters.

A high-performance instrument cannot compensate for poorly optimized reagents.

A good reagent kit cannot compensate for an unsuitable automation protocol.

And even a validated workflow needs application support when laboratories introduce new sample types or scale up throughput.

The most effective automation strategy is therefore to standardize the workflow as a whole, rather than automate individual steps in isolation.  

Yeasen Automated NGS Library Preparation Solution

Yeasen provides an integrated solution combining automation platforms, automation-ready reagents, validated workflows, and application support.

Category

Product

Cat. No.

Workstation

MGISP-960 High-Throughput Automated Sample Preparation System

-

Fluorometer

ES-FR96 Fluorometer (96-channel)

80575ES

DNA Library Prep

Hieff NGS™ OnePot Pro DNA Library Prep Kit V4 (Illumina & MGI compatible)

12972ES

Hieff NGS™ OnePot EvoMax DNA Library Prep Kit(Premixed Version) 

12112ES

Hieff NGS™ DNA Library Prep Kit 2.0 (Mechanical)

12927ES

Hieff NGS™ OnePot Evo DNA Library Prep Kit (Enzymatic, For FFPE, V4)

12193ES

RNA Library Prep

Hieff NGS™ EvoMax RNA Library Prep Kit (dUTP)

12340ES

Hieff NGS™ EvoMax RNA Library Prep Kit (dNTP)

12341ES

mRNA Enrichment

Hieff NGS™ mRNA Isolation Master Kit V2

12629ES

rRNA Depletion

Hieff NGS™ MaxUp Human rRNA Depletion Kit(Human)

12257ES

Hieff NGS™ MaxUp rRNA Depletion Kit (Plant)

12254ES

Hieff NGS™ MagSP rRNA Removal Kit (Bacteria, G− / G+)

12264ES

Methylation Library Prep

Hieff NGS™ dsDNA Methyl Library Prep Kit for Illumina

12214ES

Long-Read Library Prep

Hieff™ LongSeq Plasmid Fragmentation and Ligation Module

13305ES

Adapters

Hieff NGS™ Unique Dual Barcode Primer Kit for MGI, Set 1~Set5

13350ES~13353

Hieff NGS™ Stubby UDI Primer Kit for Illumina, Set 1~Set5

12327–12330ES

Purification Beads

Hieff NGS™ DNA Selection Beads

12601ES

Quantification

1× dsDNA HS Assay Kit / dsDNA BR Assay Kit

12642ES / 12643ES

Consumables

250 μL filtered sterile tips / 96-deep-well plate (1.3 mL) / 0.2 mL PCR plate (white, full skirt) / qPCR sealing film

83130ES / 83672ES / 83560ES / 83624ES

Quantification Plate

96-well ELISA plate, solid black (fluorometry)

83652ES

QC Instruments

Qubit assay tubes / single-channel fluorometer

83509ES / 80571ES

Contamination Control

Non-Corrosive Nucleic Acid Remover

19710ES

NGS automation is not simply about replacing manual pipetting with a robot.

The real objective is to build a workflow that can scale without sacrificing consistency, flexibility, or data quality.

That means looking beyond the instrument and evaluating the complete workflow — from reagents and scripts to QC and application support.

Before investing in automation, ask one final question:

Are you automating the instrument, or are you standardizing the entire library preparation workflow?

Förfrågan