In modern biomedical research, luciferase reporter gene assays have become indispensable tools for quantifying gene expression, signaling pathway activity, and drug target responses with exceptional sensitivity. By capturing the bioluminescent signal generated during the enzymatic oxidation of luciferase substrates—such as firefly luciferase—these assays enable real-time, noninvasive, and highly quantitative readouts of molecular events within living cells.
However, traditional luciferase assays often suffer from labor-intensive workflows, rapid signal decay, and batch-to-batch inconsistencies. Such limitations pose significant challenges for high-throughput drug discovery and regulatory-compliant biopharmaceutical development, where data accuracy, reproducibility, and operational simplicity are critical.
ICH-Guided Pre-Validation for Industrial-Grade Reliability
To meet the evolving demands of high-throughput and precision pharmacology, Yeasen Biotech has developed a new generation of Luciferase Reporter Gene Detection Reagents, rigorously prevalidated according to ICH Q2 guidelines.
This next-generation formulation empowers laboratories with pharmaceutical-grade reliability and simplified workflows.
Method validation highlights include:
- Linearity: Demonstrated excellent linear correlation (R² ≥ 0.99) across 1×10³–1×10⁵ cells, supporting a broad dynamic range.
- Specificity: Delivers highly selective signal capture with negligible background interference.
- Precision & Accuracy: Coefficient of variation (CV%) consistently below 10%, ensuring superior reproducibility.
- Repeatability: Stable and consistent results across multiple replicates and batches.
A. Good linearity

B. Specificity

C. Repeatability

D. Precision and accuracy



Table 1. Potency and recovery of Zolbetuximab ADCC (n=3)
Sample |
Relative potency / % |
Recovery / % |
||
x̄±s |
CV/% |
x̄±s |
CV/% |
|
50% |
47.7±3.42 |
7.17 |
95.4±6.83 |
7.17 |
75% |
74.25±1.05 |
1.42 |
99±1.40 |
1.42 |
125% |
128.97±7.69 |
5.96 |
103.18±6.15 |
5.96 |
150% |
162.65±11.1 |
6.82 |
108.43±7.40 |
6.82 |
5-Minute One-Step Workflow for Instant Results
Traditional luciferase assays require multiple steps—cell lysis, centrifugation, buffer exchanges—that not only prolong the process but also increase the risk of manual errors and sample loss.
Yeasen’s one-component, one-step system revolutionizes this workflow:
- Lysis & Detection in One Step: Simply add the reagent directly to the cell suspension, pipette up and down five times, and incubate for five minutes to achieve complete cell lysis and signal generation.
- No Wash, No Buffer Change: Fully compatible with both adherent and suspension cells, eliminating the need for media removal or washing steps.
- Ready-to-Use Simplicity: With only one reagent required, the assay is immediately ready for detection—no mixing or additional reagents needed.

Figure 1. Luciferase Reporter Gene Assay Kit — One-Step, 5-Minute Rapid Detection Workflow
Three Tailored Solutions for Every Application
Yeasen’s luciferase reporter gene detection series combines ease of use with high sensitivity and remarkable signal stability—featuring a signal half-life exceeding five hours, ideal for high-throughput screens and long-read assays.
The series includes three optimized options to meet varying assay demands:
- Bio-One Step: Designed for routine assays requiring high speed and reliability.
- Steady-One Step: Provides enhanced signal stability for long-term monitoring.
- Bright-One Step: Delivers ultra-high sensitivity for low-expression targets or demanding drug screening environments.
Product Name |
Bio-One Step |
Steady-One Step |
Bright-One Step |
Catalog No. |
11411ES |
11413ES |
11412ES |
Application & Features |
Achieves a balance between signal intensity and stability — maintains relatively high signal strength with moderate stability over time. |
Signal half-life exceeds 5 hours; minimal signal decay within the first 2 hours. Ideal for high-throughput assays in 96- or 384-well plates. |
Provides ultra-high sensitivity and strong signal intensity. Signal remains stable for up to 10 minutes, suitable for low-expression samples requiring high sensitivity. |
Signal Half-life |
60 min |
>5 h |
30 min |
Operation |
One-step |

Figure 2. Performance comparison of Yeasen luciferase reporter assay reagents.
Tests on cells stably expressing firefly luciferase show that Bright-One Step provides the highest signal with stable intensity for 5–10 min; Steady-One Step offers exceptional stability with a signal half-life of over 5 h; and Bio-One Step delivers strong signals with balanced stability.
From Research to Drug Discovery—Accelerating Decision-Making with Confidence
Built upon ICH prevalidation principles, Yeasen’s luciferase reporter assay platform bridges the gap between academic innovation and industrial application. Whether used for gene regulation studies, cell therapy development, or high-throughput drug screening, it offers a seamless combination of speed, reproducibility, and regulatory alignment—empowering precision drug discovery with data you can trust.
Related Products
Category |
Name |
Cat. No. |
Size |
Single-Luciferase Reporter Assay Reagent |
11412ES60/80/81 |
100T/10×100T/1000T |
|
11411ES60/80/81 |
100T/10×100T/1000T |
||
11413ES60/80/81 |
100T/10×100T/1000T |
||
Dual-Luciferase Reporter Assay Reagent |
11402ES60/80 |
100T/1000T |
|
Dual One Step Luciferase Reporter Gene Assay Kit |
11405ES60/80 |
100T/1000T |