SV40LTA&E1A Residue DNA Detection Kit _ 41310ES

Yeasen제품번호: 41310ES50

Size: 50 T
가격:
판매 가격$955.00

결제 시 배송비 계산

재고:
재고 있음

설명

This kit is designed for the quantitative detection of residual host cell DNA—specifically SV40 Large T Antigen (LTA) and Adenovirus E1A sequences—in biopharmaceutical products derived from host cells such as HEK293T.

Utilizing probe-based real-time PCR (qPCR), the assay enables highly specific and rapid quantification of SV40 LTA and E1A residual DNA, with a limit of detection as low as 10¹ copies/μL.

The kit is fully compatible with Yeasen’s Magnetic Bead–Based Residual DNA Sample Preparation Kits (Cat# 18461ES) for streamlined sample processing.

Features

  • Complies with regulations – Fully validated; validation reports available.
  • High-quality reagents – All components in-house developed; enzymes made in ultra-clean facility.
  • Highly sensitive – Detection down to 10¹ copies/μL.
  • Highly reproducible – Low within-run and between-run variability.
  • Highly specific – Detects only SV40 LTA and E1A DNA—no cross-reactivity.
  • Built-in control – Internal Control (IC) flags sample or reaction issues.

Components

Components No.

Name

41310ES50(50 T)
41310ES60(100 T)

41310-A

SV40LTA&E1A qPCR Mix

0.75 mL

1.5 mL

41310-B

SV40LTA&E1A Primer&Probe Mix

200 μL

400 μL

41310-C

DNA Dilution Buffer

2 × 1.8 mL

4 × 1.8 mL

41310-D

SV40LTA&E1A DNA Control (nonliner)

25 μL

50 μL

41310-E

SV40LTA&E1A DNA Control (linear)

25 μL

50 μL

41310-F

IC

50 μL

100 μL

*IC: Internal control.

Storage

This product should be stored at -25~-15for 2 years. Both 41310-A and 41310-B should be stored protected from light.

Applicable Instrument Models

Include but not limited to:

Bio-Rad: CFX96 Optic Module.

Thermo Scientific: ABI 7500; ABI Quant Studio 5.

Figures

1. Detection Range

SV40LTA: Linear range = 1.8 × 10¹ ~ 1.8 × 10⁵ copies/μL, R² = 1.000, amplification efficiency = 100.25%, CV < 15% across all concentrations.

E1A: Linear range = 1.8 × 10¹ ~ 1.8 × 10⁵ copies/μL, R² = 1.000, amplification efficiency = 100.25%, CV < 15% across all concentrations.

Figure 1. SV40LTA standard curve (left) and amplification plot (right)https://www.yeasenbio.com/products/80510

 Figure 1. SV40LTA standard curve (left) and amplification plot (right)

&nbsp;Figure 2. E1A standard curve (left) and amplification plot (right)

 Figure 2. E1A standard curve (left) and amplification plot (right)

2. Limit of Quantitation (LOQ)

SV40LTA & E1A DNA at concentrations of 18, 9, 4.5, 2.25, and 1.8 copies/μL were tested in 10 replicates each. At ≥4.5 copies/μL, CVs were <20%, establishing the LOQ as 4.5 copies/μL.

Figure 3. qPCR detection of SV40LTA(lift) and E1A(right) at 4.5 copies/μL

 

Replicate

Analyte

SV40LTA (copies/μL)

E1A (copies/μL)

Quantity

Recovery

Quantity

Recovery

1

4.66

103.61%

4.87

108.21%

2

4.33

96.29%

4.15

92.26%

3

4.49

99.72%

4.63

102.88%

4

5.08

112.97%

4.86

107.99%

5

6.26

139.11%

5.67

125.93%

6

5.46

121.26%

4.97

110.42%

7

4.79

106.34%

5.50

122.22%

8

5.57

123.83%

5.00

111.20%

9

5.09

113.18%

5.55

123.28%

10

4.62

102.62%

4.97

110.43%

Mean

5.04

\

5.02

\

CV%

11.73%

\

9.13%

\

 Documents:

Safety Data Sheet

40310_MSDS_HB260203

Manuals

40310_Manual_Ver.EN20260203

결제 및 보안

American Express Apple Pay Diners Club Discover Google Pay Mastercard Visa

귀하의 결제 정보는 안전하게 처리됩니다. 당사는 신용카드 정보를 저장하지 않으며 귀하의 신용카드 정보에 접근할 수 없습니다.

당신은 또한 좋아할 수 있습니다

문의

자주 묻는 질문

이 제품은 연구 목적으로만 사용되며 인간이나 동물의 치료 또는 진단용으로 의도되지 않았습니다. 제품과 콘텐츠는 Yeasen Biotechnology가 소유한 특허, 상표 및 저작권으로 보호됩니다. 상표 기호는 모든 지역에서 반드시 등록되는 것은 아니지만 원산지를 나타냅니다.

특정 애플리케이션에는 추가적인 제3자 지적 재산권이 필요할 수 있습니다.

예슨은 윤리적 과학에 헌신하며, 우리의 연구가 안전과 윤리적 기준을 보장하는 동시에 중요한 문제를 해결해야 한다고 믿습니다.