설명
Hifair™ Advanced Multiplex One Step RT-qPCR Probe Mix (UDG Plus) is a reagent kit designed for multiplex quantitative PCR (qPCR) using RNA as the template. In this workflow, reverse transcription and qPCR are performed in a single reaction tube, simplifying experimental procedures and reducing the risk of contamination.
This kit employs a thermostable Reverse Transcriptase for efficient first-strand cDNA synthesis and HotStart Taq DNA Polymerase for quantitative amplification. The kit includes an optimized MP Buffer and Enzyme Mix. The buffer already contains Mg²⁺ and dNTPs, along with components that effectively suppress non-specific PCR amplification and enhance the efficiency of multiplex qPCR reactions—enabling robust multiplex amplification while maintaining primer amplification efficiency. Additionally, the dUTP/UDG system is incorporated to effectively prevent aerosol-mediated contamination.
Features
All-in-One Master Mix: Buffers and enzymes precombined in a single tube for one-step RT-qPCR setup — pipette and run.
Exceptional Stability: Maintains performance after accelerated aging at 37°C for 7 days and ≥20 freeze–thaw cycles, enabling reliable storage and transport.
dUTP/UDG anti-pollution system: Incorporates dUTP/UDG enzyme to prevent amplicon carryover contamination for cleaner results.
Components
|
Name |
16921ES50 |
16921ES60 |
16921ES80 |
16921ES92 |
|
5×RT-qPCR Master Mix |
250 μL |
500 μL |
5 mL |
50 mL |
Storage
This product should be stored at -25~-15℃ for 1 year.
Application
RT-qPCR Detection; Diagnostic pathogen detection (respiratory tract, intestinal tract, etc.); animal pathogen detection (non-swine fever, etc.); food testing (microorganisms, etc.).
Figures
1. High sensitivity&Batch-to-Batch Stability

Figure 1.Three-Batch Performance Evaluation (Sensitivity and Positive Control Testing)
A 10-fold serial dilution of real sample template (Ct 36–40) was tested in eight replicates to assess sensitivity across three production batches. In parallel, two-well amplification of the positive control was performed to evaluate overall amplification performance and batch consistency.
2. Strong stability

Figure 2. Thermal accelerated stability testing
Two batches of Yeasen 16921 reagents were stored at 37°C for 3 days and compared with reagents kept under standard storage conditions. PRRSV real samples and positive controls were amplified in parallel. The Ct values of both target and positive control remained consistent across conditions, and all samples were successfully detected.
Documents:
Safety Data Sheet
Manuals
결제 및 보안
귀하의 결제 정보는 안전하게 처리됩니다. 당사는 신용카드 정보를 저장하지 않으며 귀하의 신용카드 정보에 접근할 수 없습니다.
문의
당신은 또한 좋아할 수 있습니다
자주 묻는 질문
이 제품은 연구 목적으로만 사용되며 인간이나 동물의 치료 또는 진단용으로 의도되지 않았습니다. 제품과 콘텐츠는
특정 애플리케이션에는 추가적인 제3자 지적 재산권이 필요할 수 있습니다.
예슨은 윤리적 과학에 헌신하며, 우리의 연구가 안전과 윤리적 기준을 보장하는 동시에 중요한 문제를 해결해야 한다고 믿습니다.