Firefly Glo Luciferase Reporter Gene Assay Kit _ 11404ES

Yeasen제품번호: 11404ES60

Size: 100 T
가격:
판매 가격$115.00
재고:
재고 있음

Firefly luciferase is a protein with a molecular weight of approximately 61 kDa. In the presence of ATP, magnesium ions, and oxygen, it catalyzes the oxidation of luciferin to oxyluciferin. During the oxidation of luciferin, bioluminescence at a wavelength of approximately 560 nm is emitted, which can be measured using a luminometer.

Figure 1. Detection Principle of Firefly Luciferase

The Firefly Glo Luciferase Reporter Gene Assay Kit is a glow-type firefly luciferase reporter gene assay kit featuring high sensitivity and stable luminescence signal, which can meet the requirements of high-throughput detection of luciferase expression in mammalian cells.
Compared with the flash-type Firefly Luciferase Reporter Gene Assay Kit (Cat#.11401), this product has the following advantages: 1) More stable luminescence signal, providing greater flexibility for experimental design. 2) Adopting an add-mix-read operation method, no need for auto-injectors, and no need to discard culture medium, centrifuge, or perform other steps, greatly simplifying the experimental workflow. 3) No obvious irritating odor.
This kit is compatible with various commonly used cell culture media: RPMI 1640, DMEM, MEM-alpha, F12, DMEM/F12, etc., with a half-life of approximately 2 hours (22°C), meeting the needs of most high-throughput experiments.

Product Information

Product Name

Catalog No.

Size

Firefly Glo Luciferase Reporter Gene Assay Kit

11404ES60

100 T

11404ES80

1,000 T

Components

Component No.

Component Name

11404ES60 (100 T)

11404ES80 (1,000 T)

11404-A

Firefly Glo Luciferase Assay Buffer

10 mL

100 mL

11404-B

Firefly Glo Luciferase Substrate

1 vial

1 vial

Features

Stable Signal: Long signal half-life of up to 2 h, ideal for high-throughput detection

Simple Workflow: Simply add the sample and read the result.

Broad Medium Compatibility: Compatible with common culture media, including RPMI 1640, DMEM, MEM-α, F12, and DMEM/F12.

Storage

Transported on dry ice. Store the unopened kit at -20 °C , valid for 1 year. The dissolved and aliquoted glow-type firefly luciferase substrate should be stored at -70 °C protected from light for 1 year, or at -20 °C for no more than 1 month.

FAQ

No. An instrument with a bioluminescence module and full-wavelength detection (350-700 nm) is required, such as GloMax 20/20 (single-tube detection) or Biotex HTX multi-functional microplate reader (equipped with auto-injector).
It can be stored at -80°C, similar to protein storage methods. Lysed samples can be stored at -80°C for up to six months, or at -20°C for one month.
Dilute the lysed sample, or reduce the cell incubation time after transfection experiments.

Citations

Documents

Applications

당신은 또한 좋아할 수 있습니다

문의

자주 묻는 질문

이 제품은 연구 목적으로만 사용되며 인간이나 동물의 치료 또는 진단용으로 의도되지 않았습니다. 제품과 콘텐츠는 Yeasen Biotechnology가 소유한 특허, 상표 및 저작권으로 보호됩니다. 상표 기호는 모든 지역에서 반드시 등록되는 것은 아니지만 원산지를 나타냅니다.

특정 애플리케이션에는 추가적인 제3자 지적 재산권이 필요할 수 있습니다.

예슨은 윤리적 과학에 헌신하며, 우리의 연구가 안전과 윤리적 기준을 보장하는 동시에 중요한 문제를 해결해야 한다고 믿습니다.